Maintenance of the Compressor
LOOK OUT!
Ii is possible breakdown of the compressor because of getting foreign bodies into the suction hole.
 The compressor should not work without the air filter.
 Do not blow the suction hole by a purge dispenser. There can get into the hole foreign bodies.
To clean the air filter do as follows:
Loosen the hand nut (1) by turning counter clockwise. The cover (2) is already released.
Remove the cover (2) from the case of the air filter (5).
 Take the bush of the filter (3) and clean it by a purge dispenser. If it is necessary, replace the bush of the
filter.
Check integrity of the rubber ring (4). If it is necessary, replace it.
Insert the bush of the filter (3).
Put the cover (2) onto the case of the air filter (5).
Screw in the cover by turning hand nut (1) clockwise.

Intervals of Maintenance

Maintenance Job
Check the oil level and add if it is necessary.
Drain condensational water
Clean the receiving filter
Clean tension of the V-belt
Total cleaning compressor
Replacement of oil
Maintenance set of a (See the list of spares)
Maintenance set of b (See the list of spares)
Maintenance set of c (See the list of spares)
22
Weekly
Monthly
Every 6
Months
X
X
X
X
X
X
500 h,
1000 h,
necessarily
yearly at least
X
X
X
2000 h,
biennially at least
X
X
X