SICK WTB26 Manual Del Usuario página 12

Ocultar thumbs Ver también para WTB26:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 83
8020354.19RH / 15.01.2021 | SICK
Subject to change without notice
The sensing range can also be adjusted using just the potentiometer. We recommend
placing the sensing range in the object, e.g.
range has been adjusted, the object is removed from the path of the beam, which
causes the background to be suppressed and the switching output to change
table
4).
1
1...3 sec.
2
3
Figure 8: WTB26x-xxxxxx2xAxx, adjusting the sensing range with Teach-Turn adjustment
WTB26x-xxxxxx1xAxx with potentiometer:
The sensing range is adjusted with the potentiometer.
Clockwise rotation: Sensing range increased.
Counterclockwise rotation: Sensing range reduced.
We recommend placing the object within the sensing range, see figure 9 for an exam‐
ple. Once the sensing range has been adjusted, the object is removed from the path of
the beam, which causes the background to be suppressed and the switching output to
change
(see table
4).
COMMISSIONING
see figure 8, page
11. Once the sensing
7
(see
11

Publicidad

Tabla de contenido
loading

Tabla de contenido