Troubleshooting
If you run into any problem when using your UPX-
C200, use the following table as a guide to troubleshoot
the problem. If the problem persists, contact your Sony
dealer or local authorized Sony service facility.
Camera
Symptom
Power is not turned off
even if the POWER
switch is set to OFF.
The POWER switch of
the camera is set to ON,
but the camera and
printer are not
connected.
While Shooting
Symptom
A picture cannot be
taken when you press
the release button.
68
Troubleshooting
Possible causes/Action
• The camera requires a long period
of time for internal processing.
tWait a while, and if the power is
not turned off, disconnect the AC
power adaptor from the camera
or open the battery compartment
lid.
• The power of the printer is not
turned on.
tTurn the printer on, and then turn
the camera on.
• The Bluetooth lamp of the camera
or printer is turned off.
tTurn on both of the lamps. (See
"Turning on the Bluetooth lamp"
(on page 56).)
• "NO PRINTER" appears.
tThe registration of the printer is
cancelled. Register the printer.
(See "Adding/Registering the
Printer" in Operating
Instructions (Advanced
Operations).)
Possible causes/Action
• The PLAY/CAMERA switch is not
set to CAMERA.
tSet the switch to CAMERA.
• The camera is storing data in
memory or charging the flash (the
standby lamp is flashing in red).
tWait until the standby lamp
lights or flashes in green.
• The memory is full (the standby
lamp is lit in red).
tCheck the displayed remaining
number of pictures that can be
taken. If zero, erase any picture
that is not necessary.
tSet AUTO ERASE to ON.
(Refer to the Operating
Instructions (Advanced
Operations).)
Symptom
The flash does not light. • Flash Mode is not set appropriately.
tSet FLASH MODE in menu to
A ,
• The cord of the external flash is not
connected to the camera.
tConnect the cord of the external
flash to the FLASH jack of the
camera.
• The batteries are discharged.
tCharge the batteries or replace
them with a new one.
• The flash may be out of life.
tContact your Sony service
facility or your Sony dealer.
Liquid Crystal Display of the
Camera
Symptom
No playback picture
• The MONITOR (PAL) switch of the
appears.
camera is set to VIDEO OUT when
a video cable is connected and
VIDEO OUT of the menu is set to
PAL.
tSet the switch to LCD.
tDisconnect the video cable.
If played back in cold
Condition due to the liquid crystals.
weather, the picture
tNormal condition
may seem to present
curved sides.
The image presents
some red, blue, and
green dots, or there are
black spots visible.
Animation of paper
• The printer is printing a picture.
tWait until printing is finished.
Then try again.
Data transmission ends,
• The printer is supplying print paper.
but the display freezes
tWait until paper supply finishes
up.
and printing begins. Then the
displayed picture changes.
Possible causes/Action
or M .