WARNING
After having replaced the filters, reinstall the
front stainless steel pan'el, otherwise the
Downdraft is not enabled to function.
ELECTRICAL CONNECTION
OF THE COOKER HOOD
WARNING
Place the metal box containing the electronic
components at a distance of no less than 65
cm from gas-operated cook tops or in any
case, 65 cm from the suctioning surface of
the cookerhood.
NOTA
We recommend installing the metal box con-
taining the electronic components at least 10
cm above floor level and at a suitable distan-
ce from all heat sources (e.g. oven sides or
cook top).
CAUTION
This appliance is fitted with an H05 VVF 3 con-
ductor, 0.75 mm2 (neutral, phase, and ground)
power cord.
This can be connected up to a 220 - 240 V
mono-phase electrical network through a CEI
60083 approved power socket, which must
remain accessible after installation, in com-
pliance with installation regulations.
We decline any responsibility in case of acci-
dents caused by a lack of ground connection
or incorrect ground connection. The applian-
ce must be fed through a differential protec-
tion device (RCD), with a nominal residual
current not exceeding 30mA. If the power
cord is damaged, call the after-sales service
to avoid any risk.
18
All manuals and user guides at all-guides.com
EN
WARNING
The downdraft connection to the electrical
network must be carried out only by profes-
sional and qualified technicians.
The downdraft must be connected to a pro-
perly installed and suitable electrical network.
The electrical system must comply with
VDE0100 standard.
DANGER
If the cooker hood presents any anomaly, di-
sconnect the appliance or remove the fuse
corresponding to the appliance power di-
sconnecting line.
If the appliance has no plug or if the plug is not
easily accessible, then a device needs to be fitted
to cut it off from the electric network; this device
must have an opening distance between contacts
on all poles of at least 3 mm.
ELECTRICAL CONNECTION
This appliance complies with the European
Directives 2006/95/EC (Low Voltage Directive)
and 2004/108/EC (Electromagnetic Compati-
bility).
While installing the appliance and carrying main-
tenance operation, make sure it is disconnected
from the electrical network or the fuses are cut out
or removed.
Check that:
• Power is enough.
• Feeder lines (mains) are in good conditions.
• The cables diameter complies with installation
regulations.
NOTA
TRENTO