10. List of alarms
Indication
"Alarm" is permanently on.
"Alarm" is flashing.
11. Technical data
Data
Supply voltage
Maximum inductive contact load
Frequency
Maximum ambient temperature
Liquid temperature
*)
p
start
Q
min.
Time delay during stopping
Maximum operating pressure
Enclosure class
Dimensions
*)
The start pressure (p
start
The technical data may be limited by the pump data. See installation and operating instructions for the pump.
10
Alarm
Dry running.
Cycling.
PM 1 - 15
PM 1 - 22
) depends on the variant. See the nameplate.
Cause
The pump has been running without water.
The pump is cycling.
Note: Occurs only if the anti-cycling function is
enabled. See section
8.1
230 V model
1 x 220-240 VAC
10 A
50/60 Hz
See nameplate.
0 °C - see nameplate.
1.5 bar
2.2 bar
1.0 litre/min.
10 seconds
PN 10 / 10 bar / 1 MPa
IP65
See fig. 3, page
Anti-cycling.
115 V model
1 x 110-120 VAC
14 A
151