FEATURES
PRODUCT SPECIFICATIONS
ENGINE
Engine Type .......................Yamaha MZ300, 4 Stroke, OHV
Fuel Volume ................................................................ 6 gal.
GENERATOR
Rated Voltage .....................................................120V/240V
Rated Amps ................................................... 47.5A/23.75A
Rated Output ..........................................................5,700 W
KNOW YOUR GENERATOR
See Figure 2.
The safe use of this product requires an understanding of the
information on the product and in this operator's manual as
well as a knowledge of the project you are attempting. Before
use of this product, familiarize yourself with all operating
features and safety rules.
AC CIRCUIT BREAKER
The circuit breaker is provided to protect the generator
against electrical overload. The circuit breaker may be reset
by pressing the circuit breaker reset button.
AIR FILTER
The air filter helps to limit the amount of dirt and dust drawn
into the unit during operation.
CHOKE LEVER
The choke lever is used when starting the engine.
FUEL TANK
The fuel tank has a capacity of 6 gallons.
FUEL VALVE
Fuel flow from the fuel tank to the engine is turned on and
off using the fuel valve.
GenSmart™ MONITORING SYSTEM
The GenSmart
monitoring system tracks usage and load
™
and alerts the operator when periodic engine maintenance
is needed.
NOTE: GenSmart
load indicator monitors the load only
™
for the 120 Volt, 20 Amp GFCI outlets on the control panel.
It does not measure load on the 240 Volt, 30 Amp outlet.
Maximum Output....................................................7,125 W
Rated Frequency ........................................................60 Hz
DIMENSIONS
Length .................................................................... 33.9 in.
Width .......................................................................... 22 in.
Height ...................................................................... 22.5 in.
Weight .................................................................... 190 lbs.
GROUND TERMINAL
The ground terminal is used to assist in properly grounding
the generator to help protect against electrical shock. Con-
sult with a local qualified electrician for grounding require-
ments in your area.
LOW OIL SHUT DOWN PROTECTOR
The low oil sensor causes the engine to stop if the level of
lubricant in the crankcase is insufficient.
OFF SWITCH
To turn the engine off, press and hold the OFF switch until
the engine stops.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the
generator when necessary.
OIL DRAIN PLUG
When changing the engine lubricant, the oil drain plug is
removed to allow old engine lubricant to be drained.
RECEPTACLES
The following single phase, 60 Hz outlets on the control panel
can be used for operating appropriate equipment, electrical
lighting, tools, and motor loads: 2 x 120 Volt duplex GFCI 20
Amp receptacles, and one 240 Volt AC, 30 Amp receptacle.
RECOIL STARTER GRIP
The recoil starter is pulled to start the machine.
10 — English