Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the
starter or housing.
• With electric starter: (Optional kit)
Turn the engine switch to the START position and hold it there for 5 seconds or until the engine starts.
NOTICE
Operating the starter motor for more than 5 seconds can damage the motor. If the engine fails to start,
release the switch and wait 10 seconds before operating the starter again. If the speed of the starter motor
drops after a period of time, it indicates that the battery should be recharged.
When the engine starts, allow the engine switch to return to the ON position.
1. Turn the choke lever or push the choke rod to the OPEN position as the engine warms up.
Stopping the engine
In an emergency:
To stop the engine in an emergency, move the engine switch to the OFF position.
In normal use:
1). Turn the AC circuit breaker to the OFF position. Disconnect the DC battery charging cables.
2). Turn the engine switch to the OFF position.
3). Turn the fuel valve to the OFF position.
7. MAINTENANCE
Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution.
WARNING
Exhaust gas contains poisonous carbon modoxide. Shut off the engine before performing any
maintenance. If the engine must be run, make sure the area is well ventilated.
Periodic maintenance and adjustment is necessary to keep the generator in good operating condition. Perform the
service and inspection at the intervals shown in the Maintenance schedule below.
1) MAINTENANCE SCHEDULE
REGULAR SERVICE PERIOD Performed at
every indicated month or operating hour
interval, whichever comes first.
ITEM
Engine oil
Air cleaner
Sediment Cup
Spark plug
Spark arrester
Valve clearance
Fuel tank and strainer
Fuel line
1) Service more frequently when used in dusty areas.
2) These items should be serviced by an authorized generator dealer, unless the owner has the proper tools and is
mechanically proficient.
(3) For professional commercial use, long hours of operation to determine proper maintenance intervals.
WARNING
Improper maintenance, or failure to correct a problem before operation, can cause a malfunction in which
you can be seriously hurt or killed. Always follow the inspection and maintenance recommendations and
schedules in this owner's manual.
The maintenance schedule applies to normal operating conditions. If you operate your generator under severe
conditions, such as sustained high-load or high-temperature operation, or use it in unusually wet or dusty
conditions, consult your servicing dealer for recommendations applicable to your individual needs and use.
2) Tool kit
The tools supplied with the generator will help you to perform the owner maintenance procedures listed on the
following page. Always keep this tool kit with the generator.
Each use
Check level
o
Change
Check
o
Clean
Clean
Check-Clean
Clean
Check-Adjust
Clean
Check
First month
Every 3
or 20 Hrs.
months or
(3)
50 Hrs. (3)
o
o(1)
Every 2 years (Replace if necessary) (2)
EN
Every 6
Every year
months or
or 300 Hrs.
100 Hrs. (3)
(3)
o
o
o
o
o(2)
o(2)