INSTRUCTION MANUAL
Network digital multimeter
KPS-MT480
Cód: 602250036
SKU: KPSMT480CBINT
Network digital multimeter
ENGLISH
The meter is a portable specialized measuring instrument with a large digital LCD, as well as
a backlight source for easy reading. The range selector designed for a single-hand operation
makes measurement easy. Overload protection and low battery indication are provided, It
is an ideal multi-functional instrument with scores of practical applications for professional,
factory, school, amateur and home use.
The meter can be used to measure DC and AC voltages and currents, and resistances, teste
circuit continuity and diodes, detect phone line mode, judge break points in cable lines, track
the routing of cable lines, and detect network cable integrity and non-contact voltage.
SAFETY INFORMATION
WARNING
BE EXTREMELYCAREFULWHEN USING THE METER. lmproper use of this device can
result in electric shock or destruction of the meter. Take all normal safety precautions and
follow the safeguards suggested in this manual. To exploit full functionality of the meter and
ensure safe operation, protection provided by the instrument will be impaired if used in a
manner not specified by the manufacturer.
The Auto Range Digital Multimeter (hereinafter referred to as" the meter") complies with the
safety requirements for electronic measuring instruments in IEC-61010-1, falls into pollution
degree 2 and meets the over-voltage standard of CAT. III 600V.
Follow all safety and operation instructions to ensure safe use of the meter.
With proper use and care, the meter will give you years of satisfactory service.
PRELIMINARY
- To operate the meter, the user must observe the following normal safety rules:
1) General protection against electric shock
2) Protection of the meter against misuse
- When the meter is received, please check whether it has been damaged during transport.
- After being stored and delivered under harsh conditions, the meter should be checked and
confirmed for damage
- The test probes must be kept in good condition. Check whether the insulation of the test
probes has been damaged and whether any wire has been exposed.
- Using the test probes supplied can ensure safety. If required, they must be replaced with
those of the same model or class.
DOS AND DON´TS
- Use the right input jack, function and range.
- Do not take measurements beyond the protection limits indicated in the specifications.
- Do not touch the metal tips of the test probes when connecting the meter to the circuit to
be measured.
- Keep your fingers behind the probe barriers when taking a measurement with an effective
voltage of above 60V DC or 30V AC.
- Do not take any voltage measurement if the value between the measuring terminal and
the ground exceeds 1000V.
- Select the highest range if the value to be measured in the manual range is known.
- Do not connect the meter to any voltage source while the meter is in the current, resistance,
diode or continuity test range.
- Disconnect the test probes from the circuit under test before turning the range selector to
change functions.
- Be careful in that high voltage pulses at the test point may damage the meter when
measurements are being taken on the switching power circuit of a TV set.
- Do not measure the resistance, diode or continuity of live circuits.
- Do not use the meter near explosive gases, steam or dirt.
- Stop using the meter if any abnormalities or faults are noticed.
- Do not use the meter unless its rear case is securely fastened in its original position.
- Do not store or use the meter in areas exposed to direct sunlight, high temperatures or
high humidity.
PRECAUTIONS
- Do not adjust or repair the meter by attempting to remove the rear case. Such operation
should only be performed by a technician who fully understands the meter and the electric
shock risk involved.
- Remove the test probes from the circuit under test before opening the battery cover of
the meter.
- To avoid any electric shock caused by erroneous readings, replace the batteries
immediately when the "
" symbol appears on the LCD.
- To avoid fire hazards, the replacement fuse must meet the specified voltage and current
ratings of F10A/500v and F200mA/1000V (quick acting).
- Use wet cloth and mild detergent to clean the meter; do not use abrasives or solvents.
- Turn to OFF switch off the power when is not in use.
- Remove the batteries to avoid damages to the meter if it will idle for a long time.
- Using this appliance in an environment with a strong radiated radio-frequency
electromagnetic field (approximately 3V/m) may influence its measuring accuracy. The
measuring result can be strongly deviating from the actual value.
MAINTENANCE
Replacemento of batteries
Before opening the battery cover of the meter, remove the test probes from the circuit under
test to avoid the risk of electric shock.
- When the
symbol is displayed, the batteries should be replaced immediately.
- Turn the range selector to OFF and remove the test wires from the input terminals.
- Unfasten the screws and remove the battery cover.
- Mount new batteries, replace the battery cover and fasten the screws.
Replacement of fuse
EN
Before opening the battery cover of the meter, remove the test probes from the circuit under
test to avoid the risk of electric shock.
To avoid fire hazards, be sure to use the designated fuse (at rated voltage, amperage and
blow rate)
- Turn the range selector to OFF and remove the test leads from the input terminals.
- Remove the protective cover and unfasten the screws.
- Remove the rear case, pry up one end of the fuse gently and then remove the fuse from
the clip.
- After a new fuse is mounted, replace the rear case and fasten the screws.
Replacing test probes
Replace test leads if leads become damaged or worn.
Use meet EN61010-031 standard, rated CAT.III 600V, or better test leads.
ACCESORIOS
1) Test probes
2) Test connect live
3) Receiver
4) Protective cover
5) Remote unit
6) Short operation manual
APAC: MGL GLOBAL SOLUTIONS LTD
info.apac@mgl-intl.com
Flat 4-1, 4/F, No. 35, Section 3 Minquan
East Road. Taipei, Taiwan.
Tel: +886 2-2508-0877
EMEA: MGL EUMAN S.L.
info.emea@mgl-intl.com
Parque Empresarial Argame, 33163
Morcín. Asturias, Spain.
Tel: +34 985-08-18-70
Network digital multimeter
WARNING
WARNING
WARNING
1 pair
1 unit
1 unit
1 unit
1 unit
1 unit
See the full
instruction manual:
AMERICAS: MGL AMERICA, LLC.
info.na@mgl-intl.com
US East Coast: 2810 Coliseum Centre
Drive, Ste. 100. Charlotte, North Carolina,
28217 USA
Tel: +1 833 533-5899
US West Coast: 760 Challenger Street.
MGL EUMAN, S.L.
Brea, California 92821 USA
Parque Empresarial de Argame,
Tel: +1 310-728-6220
C/Picu Castiellu, Parcelas i-1 a i-4
E-33163 Argame, Morcín
www.mgl-intl.com
Asturias, España, (Spain)