Ejemplos de mensajes MIDI actuales
<Example 1> 95 3E 5F
9n is the Note-on status, and n is the MIDI channel number. Since 2H = 2, 3EH = 62, and
5FH = 95, this is a Note-on message with MIDI CH = 6, note number 62 (note name is D4),
and velocity 95.
<Example 2> C9 20
CnH is the Program Change status, and n is the MIDI channel number. Since 9H = 9 and
20H = 32, this is a Program Change message with MIDI CH = 10, program number 33.
<Example 3> E4 00 28
EnH is the Pitch Bend Change status, and n is the MIDI channel number. The 2nd byte
(00H=0) is the LSB and the 3rd byte (28H=40) is the MSB, but Pitch Bend Value is a signed
number in which 40 00H ( = 64 x 128 + 0 = 8192) is 0, so this Pitch Bend Value is
28 00H - 40 00H = 40 x 128 + 0 - (64 x 128 + 0) = 5120 - 8192 = -3072
If we assume that the Pitch Bend Sensitivity is set to two semitones, the pitch will change
only -200 cents for a Pitch Bend value of -8192 (00 00H). Thus, this message is specifying a
Pitch Bend of -200 x (-3072) / (-8192) = -75 cents on MIDI channel 5.
<Example 4> B4 64 00 65 00 06 0C 26 00 64 7F 65 7F
BnH is the Control Change status, and n is the MIDI channel number. For Control Changes,
the 2nd byte is the control number, and the 3rd byte is the value. In a case in which two or
more messages consecutive messages have the same status, MIDI has a provision called
"running status" which allows the status byte of the second and following messages to be
omitted. Thus, the above messages have the following meaning.
B4 64 00
MIDI ch.5, lower byte of RPN parameter number:
(B4) 65 00
(MIDI ch.5) upper byte of RPN parameter number:
(B4) 06 0C
(MIDI ch.5) upper byte of parameter value:
(B4) 26 00
(MIDI ch.5) lower byte of parameter value:
(B4) 64 7F
(MIDI ch.5) lower byte of RPN parameter number:
(B4) 65 7F
(MIDI ch.5) upper byte of RPN parameter number:
In other words, the above messages specify a value of 0C 00H for RPN parameter number
00 00H on MIDI channel 5, and then set the RPN parameter number to 7F 7FH.
RPN parameter number 00 00H is Pitch Bend Sensitivity, and the MSB of the value indicates
semitone units, so a value of 0CH = 12 sets the maximum pitch bend range to +- 12
semitones (1 octave). (On GS sound sources the LSB of Pitch Bend Sensitivity is ignored, but
the LSB should be transmitted anyway (with a value of 0) so that operation will be correct
on any device.)
Once the parameter number has been specified for RPN or NRPN, all Data Entry messages
transmitted on that same channel will be valid, so after the desired value has been
transmitted, it is a good idea to set the parameter number to 7F 7FH to prevent accidents.
This is the reason for the (B4) 64 7F (B4) 65 7F at the end.
It is not desirable for performance data (such as Standard MIDI File data) to contain many
events with running status as given in <Example 4>. This is because if playback is halted
during the song and then rewound or fast-forwarded, the sequencer may not be able to
transmit the correct status, and the sound source will then misinterpret the data. Take care
to give each event its own status.
It is also necessary that the RPN or NRPN parameter number setting and the value setting
be done in the proper order. On some sequencers, events occurring in the same (or
consecutive) clock may be transmitted in an order different than the order in which they
were received. For this reason it is a good idea to slightly skew the time of each event (about
1 tick for TPQN =96, and about 5 ticks for TPQN =480).
* TPQN : Ticks Per Quarter Note
Ejemplo de un mensaje Exclusivo y cálculo de una
Suma de comprobación
Roland Exclusive messages (RQ1, DT1) are transmitted with a checksum at the end (before
F7) to make sure that the message was correctly received. The value of the checksum is
determined by the address and data (or size) of the transmitted exclusive message.
How to calculate the checksum
(hexadecimal numbers are indicated by "H")
The checksum is a value derived by adding the address, size and checksum itself and
inverting the lower 7 bits.
Here's an example of how the checksum is calculated. We will assume that in the exclusive
message we are transmitting, the address is aa bb cc ddH and the data or size is ee ff gg
hhH.
aa + bb + cc + dd + ee + ff + gg + hh = sum
sum / 128 = quotient ... remainder
128 - remainder = checksum
(However, the checksum will be 0 if the remainder is 0.)
<Example 1> Setting Trigger Mode of Pad A5 in temporary patch to "Gate".
According to the "Parameter address map", the temporary patch has an address of 01 00 00
00H, Pad A5 has a offset address of 14 00H and Trigger Mode has a offset address of 10H.
Thus,
01 00 00 00
14 00
+)
10
01 00 14 10
00H
and "Gate" is a value of 01H,
00H
0CH
F0
41
00H
(1)
(2)
7FH
7FH
(1) Exclusive status, (2) ID number (Roland), (3) Device ID (17)
(4) Model ID (HPD-15), (5) Command ID (DT1), (6) EOX
Next we calculate the checksum.
01H + 00H + 14H + 10H + 01H = 1 + 0 + 20 + 16 + 1 = 38 (sum)
38 (sum) / 128 = 0 (quotient) ... 38 (remainder)
checksum = 128 - 38 (remainder) = 90 = 5AH
This means that F0 41 10 00 20 12 01 00 14 10 01 5A F7 is the message we transmit.
<Example 2> Requesting transmission of Resonance Limit of temporary patch.
According to the "Parameter address map",the temporary patch has an address of 01 00 00
00H, patch common parameter has a offset address of 40 00H and Resonance Limit has a
offset address of 01H. Thus,
01 00 00 00
40 00
+)
01
01 00 40 01
Since Size = 00 00 00 01H,
F0
41
10
(1)
(2)
(3)
(1) Exclusive status, (2) ID number (Roland), (3) Device ID (17)
(4) Model ID (HPD-15), (5) Command ID (RQ1), (6) EOX
Next we calculate the checksum.
01H + 00H + 40H + 01H + 00H + 00H +00H + 01H = 1 + 0 + 64 + 1 + 0 + 0 + 0 + 1 = 67 (sum)
67 (sum) / 128 = 0(quotient) ... 67 (remainder)
checksum = 128 - 67 (remainder) = 61 = 3DH
This means that F0 41 10 00 2E 11 01 00 40 01 00 00 00 01 3D F7 is the message we transmit.
Implementación MIDI
10
00 2E
12
01 00 14 10
(3)
(4)
(5)
address
00 2E
11
01 00 40 01
00 00 00 01
(4)
(5)
address
size
01
??
F7
data
checksum
(6)
??
F7
checksum
(6)
103