Electrical tester
Technical Specifications
Temperature: 23±5℃.Relative humidity: <75%
AC Current
Range
Resolution
200A
0.1A
• Maximum input current: 200A AC
• Frequency Range: 40 ~ 400Hz
DC Current
Range
Resolution
600µA
0.1µA
1000µA
1µA
• Maximum input current: 1000µA DC
DC Voltage
Range
Resolution
600mV
0.1mV
6V
0.001V
60V
0.01V
600V
0.1V
• Input impedance: 10MΩ
• Maximum input voltage: 600V DC/AC rms
Note:
At small voltage ranges, unsteady readings will appear
before the test leads make contact with the circuit. This is
normal since the meter is highly sensitive. When the test
leads are connected to the circuit, the true reading will be
shown.
Accuracy
±(3.0% reading+3 digits)
Accuracy
±(1.0% reading+4 digits)
Accuracy
±(0.7% reading+3 digits)
45
17
Electrical tester
AC Voltage
Range
Resolution
6V
0.001V
60V
0.01V
600V
0.1V
• Input impedance: 10MΩ
• Maximum input voltage: 600V DC /AC rms
• Frequency Range: 40 ~ 400Hz
Note:
At small voltage ranges, unsteady readings will appear
before the test leads make contact with the circuit. This is
normal since the meter is highly sensitive. When the test
leads are connected to the circuit, the true reading will be
shown.
LOZ
Range
Resolution
ACV
1-600V
DCV
1-600V
• Input impedance: 10M
• Maximum input voltage: 600V DC/AC rms
• ACV Frequency Range: 40 ~ 400Hz
Note:
At small voltage ranges, unsteady readings will appear
before the test leads make contact with the circuit.
This is normal since the meter is highly sensitive.
When the test leads are connected to the circuit,
the true reading will be shown.
Accuracy
±(0.8% reading+3 digits)
Accuracy
±(2.0% reading+3 digits)
46
18