2 Set rotary switch at desired Hz position.
3 Push Hz% button to select% mode and connect the test lead tips in parallel
with the circuit to be measured.Be careful not to touch any electrical conduc-
tors.
4 Read the measure result directly from LCD display.
9.
SPECIFICATIONS
Accuracy is given as ±(% of reading+ number of least significant digits) at 18"C
to 28"C,with relative humidity up to 80%. All specifications assume less than
one year since calibration.

9.1 GENERAL SPECIFICATIONS

Maximum voltage
Display
Ranging method
Polarity indication
Overrange indication
Jaw capability
Power
Low battery
Operating temperature
Storage temperature
Temperature coefficient
Altitude
Size
Weight
KPS-PA40 • Digital clamp meter
CAT II 1000V and CATIII 600V
LCD 3999 counts, Updates 2-3/seg.
Auto range mode
"-" display for negative polarity
Only figure "OL" on the display
42mm (max conductor size)
Battery 9V IEC 6F22 JIS 006P NEDA
1604
Symbol "
" appears on the display
5 ºC to 35°C
-10 ºC to 50°C
0,1 x 1xspecified accuracy / °C (<18°C
or > 28°C)
2000 m
250mm x 99mm x 43mm
Approx. 480 g.