Carbest CARA-MOVE Manual Del Usuario página 64

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 112
Troubleshooting
System errors can occur for numerous reasons. If persistent, contact your caravan mover dealer. Use
the table below for reference and troubleshooting.
In any given LED indication, errors will be stated in the following way:
Constant on
All system errors are accompanied by an alarm from the handset, this will clear alongside the flashing
after around 8 seconds, or until the error has corrected. Various errors are listed below:
(RED) LED
Status
Over Currenta (Motor)
2 Flashes
Over Current (Battery)
3 Flashes
Under Voltage
4 Flashes
Over Voltage
5 Flashes
Over Temperature
Critical Low Voltage
6 Flashes
Lockout
M2 Motor Driver Failure
M3 Motor Driver Failure
8 Flashes
M2 and M3 Motor Driver
Failure
Flashing - up to 8 times
Description
Usually caused by overworking system, avoid excess load or steep slopes,
check vehicle brakes are not engaged.
Usually caused by a low/flat battery, check voltage.
Usually caused by an incompatible battery, or when a charging system is in
place whilst operating.
Usually caused by prolonged use on a heavy load.
- Allow 5 minutes for electronics to cool down.
- Break long periods of travel into shorter 'trips'.
Usually caused by a loose or dry connection in wiring or use of an end of life
battery.
- Ensure system is powered off, Check wiring and terminal condition.
- Verify battery condition through proper means (do not rely on internal cara-
van battery monitor).
Triggered when output voltage is not detected:
- Possible short circuit on the motor.
- Possible controller failure.
Cycle power, if problem persists, do not use again and contact dealer for
support.
Possible Cause and Action