Introduction
This manual is an integral part of the dryer you bought, and must remain with the machine even if this will be resold.
It is highly recommended that the qualified*personnel for installation maintenance and/or control will fully comply with the contents of
this manual and the prevention and safety rules in force in the country where the system will be used. In this way, not only the usage of
the machine will be rational, but also the service will result cost effective.
In case your dryer will present any kind of problem, please contact your local authorized OMI distributor.
Please note that, when necessary, the use of original spare parts will ensure efficiency and long duration to your dryer.
Due to the continuous technological evolution, OMI reserves the right to modify the specifications contained in this manual without
giving previous notice.
Symbols and labels used in the manual and on the dryer
or
or
Read the Operators manual before attempt to start
up the machine and to perform any service
operation on the dryer.
Pay particular attention to the indications preceded
by these symbols.
Installation, maintenance, and/or control operations
preceded by these symbols must be performed
exclusively by qualified personnel*.
Condensate drain point.
Pay particular attention to the risk of moving parts
Attention:
maintenance operation on this machine, do
not forget to disconnect the electric supply,
to completely discharge air pressure, and
to refer to the Operators manual
* Qualified personnel must be trained and certified in accordance with local laws and regulations.
Warranty
Each product is delivered regularly tested, and covered by the warranty conditions specified on the sale list and/or on the supply
contract.
1. GENERAL INFORMATION
1.1 Functional description
OMI refrigerated air dryers remove moisture from compressed air. Moisture is detrimental to pneumatically operated appliances,
controls, instruments, machinery and tools.
Compressed air enters the patented aluminum heat exchanger where it is cooled down to the dew point temperature in two different
stages: In the first air/air sector compressed inlet air is cooled thanks to the colder compressed air coming out counterflow from the
condensate separator. In the second refrigerant / air sector, compressed air temperature is further lowered to the dew point
temperature. During this two stages almost all the oil and water vapours contained in compressed air are condensed to liquid and
successively be separated from the compressed air in the condensate separator and drained out by the automatic drain. At this point
Cod. 710.0159.01.00 Rev01 – 10.2012
Air inlet.
or
Before
performing
- Turn main power switch on position 1.
- Push the ON/OFF button.
- There is a variable delay before the dryer will start after the dryer is turned on, in order to warm
up compressor oil.
- EN -
or
Pay particular attention to components or systems
under pressure.
Pay particular attention to hot surfaces.
Pay particular attention to the risk of electric shock.
Rotation direction of the fan.
any
Air outlet.
or
or
4 - 106