After installation, the unit becomes a "C type" with sealed chamber and forced draught.
The air inlet and fume outlet must be connected to one of the extraction/suction systems
specified below. The unit is approved to operate with all the Cxy flue configurations given
in these instructions. Some configurations may be expressly limited or not permitted by
law, standards or local regulations. Before proceeding with installation, check and care-
fully observe the above instructions. Also, comply with the provisions on the positioning
of wall and/or roof terminals and the minimum distances from windows, walls, ventilation
openings, etc.
B
This C-type unit must be installed using the inlet and fume exhaust ducts sup-
plied by the manufacturer in compliance with UNI-CIG 7129/92. Failure to use
them automatically invalidates every warranty and relieves the manufacturer of
any liability.
Expansion
For fume exhaust pipes longer than 1 metre, during installation take in account
A
the natural expansion of the materials when the boiler is operating.
To prevent deformations, leave an expansion space of approx. 2 ÷ 4 mm for
every metre of pipe.
2 ÷ 4 mm
fig. 24 - Expansion
Connection with coaxial pipes
fig. 25 - Examples of connection with coaxial pipes (
The unit is arranged standard for coaxial connection. Only use ducts with inside in stain-
less steel. Any horizontal sections of the fume exhaust must be kept sloping slightly to-
wards the outside, to prevent condensate from flowing back towards the unit.
Before proceeding with installation, check with table 2 that the maximum permissible
length is not exceeded, bearing in mind that every coaxial bend gives rise to the reduc-
tion indicated in the table. For example, a Ø 80/125 duct comprising a 90° bend + 1 ver-
tical metre has a total equivalent length of 2 metres.
Table. 2 - Coaxial duct lengths
Model
Max. permissible length
Reduction factor 90° bend (80/125)
Reduction factor 45° bend (80/125)
Reduction factor Terminal (horizontal/vertical)
Connection with separate pipes
fig. 26 - Examples of connection with separate pipes (
Before proceeding with installation, check the baffle to be used and make sure the max-
imum permissible length has not been exceeded, by means of a simple calculation:
38
EN
All manuals and user guides at all-guides.com
1.
2.
3.
Table. 3 - Separate ducts
Model
Max. permissible length
Table. 4 - Accessories
Ø 80
Ø 100
= Air /
= Fumes)
Burner setting
After carrying out the conversion, it is necessary to adjust the burner according to the
values given in table 5.
Table. 5 - Burner adjustment with sealed chamber kit
COAXIAL 80/125
Boiler
ATLAS D 30 F SI UNIT
model
6 m
1 m
ATLAS D
0.5 m
30 SI UNIT
1 m
= Air /
= Fumes)
cod. 3540S516 - Rev. 01 - 03/2015
ATLAS D 30 SI UNIT
Completely establish the layout of the system of split flues, including accessories
and outlet terminals.
Consult the table 4 and identify the losses in m
ponent, according to the installation position.
Check that the sum total of losses is less than or equal to the maximum permissible
length in table 3.
PIPE 0.5 m M/F
1KWMA38A
1 m M/F
1KWMA83A
2 m M/F
1KWMA06K
BEND 45° F/F
1KWMA01K
45° M/F
1KWMA65A
90° F/F
1KWMA02K
90° M/F
1KWMA82A
90° M/F + Test point
1KWMA70U
PIPE SECTION with test point
1KWMA16U
for condensate drain
1KWMA55U
TEE for condensate drain
1KWMA05K
TERMINAL air, wall
1KWMA85A
fumes, wall with antiwind
1KWMA86A
FLUE Split air/fumes 80/80
1KWMA84U
Fume outlet only Ø80
1KWMA83U +
1KWMA86U
REDUCTION from Ø80 to Ø100
1KWMA03U
from Ø100 to Ø80
PIPE 1 m M/F
1KWMA08K
BEND 45° M/F
1KWMA03K
90° M/F
1KWMA04K
TERMINAL air, wall
1KWMA14K
fumes, wall with antiwind
1KWMA29K
Heating
Burner
Burner
Nozzle
capacity
model
capacity
US
kW
kg/h
Angle
Gall/h
(equivalent metres) of every com-
eq
Separate ducts
ATLAS D 30 SI UNIT
25 m
eq
Losses in m
eq
Air
Fume exhaust
inlet
Vertical
Horizontal
0.5
0.5
1.0
1.0
1.0
2.0
2.0
2.0
4.0
1.2
2.2
1.2
2.2
2.0
3.0
1.5
2.5
1.5
2.5
0.2
0.2
-
3.0
-
7.0
2.0
-
-
5.0
-
12.0
-
4.0
0.0
0.0
1.5
3.0
0.4
0.4
0.8
0.6
1.0
0.8
1.3
1.5
-
-
3.0
Pump
Head
Air
pressure
adjustment
adjustment
Code
Bar
L
Notch
10
22
11