• The LED (m) lights. The device is now in the manual mode.
Inclinations along the X-axis: Align the X1 axis in the desired
direction of inclination.
Press the E
or
X-axis.
Inclinations along the Y-axis: Align the Y1 axis in the desired
direction of inclination.
Press the F
or
Tbuttons to adjust the slope in the Y-axis
• To return the self-leveling mode; press the button (M). The
LED (m) turns off.
INFRARED REMOTE CONTROL
Point the remote perpendicular to any side of the unit.
Usable functions:
1. Rotation
2. Scanner
3. Slope
RECEIVER
3/4 keys (depending on the model)
1. ON/OFF (switch on / off)
2. Activate / Deactivate acoustic signal
3. Selection of the measurement sensitivity (fine or medium or
mm/inch)
4. Activate / Deactivate backlighting
buttons to adjust the slope in the
CALIBRATION CONTROL
PLAN HORIZONTAL
X1
Place the unit about 30 meters from a wall, such as in the a.m.
drawing. Place the device with the axis X1 to the wall.
Turn on the device and mark the horizontal beam (point h1).
Turn the device through 180 ° and mark the horizontal beam
(point h2).
The vertical distance between two points (h1 and h2) should be
less than 3 mm.
Repeat the process for the Y-axis.
X1 POINT LASER
X2 POINT LASER
ENVIRON 30 METRES
h1
h2