TASMB AND TAWMB SERIES
TARGET PRESETS (PSET)
a target, minimum, maximum (over range) and batch count value. PSETs are stored in non-volatile
memory so that they are retained while power is off.
Note: After adding a Preset (see below), navigate between manual target torque, angle mode
and PSET screen by repeatedly pressing ENTER button. While PSET screen is displayed, press
ADDING A TORQUE PRESET
1. From manual target torque screen, select units of measure.
2. Press and hold UNITS button for 3 seconds.
buttons then press ENTER button. NO menu selection returns to main menu without adding a PSET.
4. TARGET TORQUE screen is displayed. TARGET TORQUE is target value of fastener. Initial
TARGET TORQUE value is value from target torque screen. TARGET TORQUE can be set to any
value within wrench torque range by pressing UP/DOWN buttons. Once desired target torque value
has been set, press ENTER button.
5. MINIMUM TORQUE screen is displayed. MINIMUM TORQUE is value at which green progress lights,
audible alert and vibrator turn on. Initial MINIMUM TORQUE value is value from target torque screen.
MINIMUM TORQUE can be set to any value from TARGET TORQUE to tool minimum torque range by
pressing UP/DOWN buttons. Once desired minimum torque value has been set, press ENTER button.
6. MAXIMUM TORQUE screen is displayed next. MAXIMUM TORQUE is torque value above which
red progress lights turn on. Initial MAXIMUM TORQUE value will be MINIMIUM TORQUE value plus
4%. Maximum torque value can be set greater than TARGET TORQUE value to 10% above wrench
maximum range by pressing UP/DOWN buttons. Once desired maximum torque value has been set,
press ENTER button.
7. BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press
UP/DOWN buttons to increment/decrement batch count. Mode Count increments each time target