Before using, always subject the pump to a visual inspec-
tion.
A pump which is damaged should not be used. In the
event of damage, have the pump checked by GARDENA
Service.
Damaged connecting cables to the pump can only be
replaced by GARDENA Service.
Disconnect the plug-in power supply from the outlet
socket for all work on the holiday watering.
The pump may only be operated with 14-V protected
low-voltage in combination with the GARDENA plug-in
power supply for pump.
Protect from rain. Use the plug-in power supply only in
a rain-protected area.
2. SCOPE OF DELIVERY
[ Fig. D1 ]:
Art. 1265 / 1266
(1)
1 x Plug-in power supply with timer for pump
(2)
1 x Submersible pump (operating voltage 14 V)
(3)
9 m Supply Pipe ∅ 4.6 mm (3/16")
(4)
6 x Sleeves
(5)
2 x End Caps (for water pump)
3. INSTALLATION
DANGER! Risk of injury!
Risk of injury when the product starts
accidentally.
v Disconnect the product from the mains before
you install the product.
To calculate the water quantity:
The Holiday Watering system allows up to 36 plants to be
watered (by using one drip pipe per plant). Here, all 3 drip
distributors must be used.
Drip distributor:
There are 3 drip distributors with different daily application
rates. Each drip distributor has 12 connections for drip
pipes.
– Light grey: For plants with low water requirements
(application rate 15 ml per day = slightly less than
a shot glass).
– Medium grey: For plants with average water
requirements (application rate 30 ml per day
= 1.5 shot glasses).
– Dark grey: For plants with high water requirements
(application rate 60 ml per day = 3 shot glasses).
If a plant has a water requirement of over 60 ml per day,
you will need to use more than one drip pipe for the plant.
1265-20.960.02.indb 11
Personal safety
DANGER! Risk of suffocation!
Small parts can be easily swallowed. There is also
a risk that the polybag can suffocate toddlers. Keep
toddlers away when you assemble the product.
Only use Original GARDENA parts, as the function of the
system cannot otherwise be guaranteed.
Do not let the pump run dry.
Observe the minimum water level in accordance with the
technical Data given for the pump.
Do not use the product while you are tired or under the
influence of drugs, alcohol or medication. A moment
of inattention while you operate the product may result in
serious personal injury.
Do not open the pump further than delivery status
(only exception: the foot).
(6)
3 x Drip distributors (light grey, medium grey, dark grey)
(7)
20 x Plugs (for drip distributors)
(8)
30 m Drip pipe ∅ 2 mm
(9)
36 x Pipe pegs
Art. 1266
(10)
1 x Container (9 l)
Calculation example:
– You have:
8 plants with low water requirements (15 ml/day)
6 plants with average water requirements (30 ml/day) and
3 plants with high water requirements (60 ml/day)
– One drip pipe should be used to water each plant.
– The water quantity should be sufficient for 14 days.
Daily requirement
= 8 x 15 ml + 6 x 30 ml + 3 x 60 ml
= 120 ml + 180 ml + 180 ml
= 480 ml ∼ 0,5 litres
Water quantity for 14 days
= daily requirement x days
= 0.5 litres x 14 days
= 7 litres
v You will need a container which can hold more than
7 litres (as a certain amount of water will also evaporate
from the container in 14 days).
For Art. 1266 Holiday Watering Set with container,
the 9-litre-capacity reservoir is included in the contents.
Group plants appropriate to the drip distributor
[ Fig. O1 ]:
Tip: When arranging your plants in groups, choose
a place that is not too close to the window (and thus
11
21.02.20 09:05