Warnings for cleaning
All cleaning of all parts must be carried out
with the stove completely cold and the plug
disconnected.
Before effecting any maintenance operation
or cleaning on the stove, take the following
precautions:
• be sure that all parts of the stove are cold
• be sure that the ashes are completely cold;
• be sure that the general switch is in the "OFF"
position;
• be sure that the plug is pulled out of the socket
to avoid accidental contact;
• Once the maintenance phase is completed
check that everything is in order as per before
the intervention (the brazier is placed correctly).

Problems and solutions

All repairs must be carried out exclusively by a specialised technician, with the
stove completely cold and the electric plug pulled out. Is prohibited from any
unauthorized modi cation to the device and the replacement of parts with other
non-original. The operations marked in bold type must be carried out by special-
ised personnel.
Check for proper combustion of the shape and color of the ame
PROBLEM
The ame thickens
at the base and the
tip has not pulled
upwards.
Flame swollen and
bursting with color
from orange to yellow
with dark tips
In normal combustion, the ame should have a tapered shape, compact, with character "lively" and
with the tips tend to be vertical or crushed towards the back of the rebox. You have to have the
feeling that the ame is pulled upwards.
102
POSSIBLE CAUSE
1. Bad regulation that
determines:
• Too full of pellets
• Low fan speed
2. The duct is obstructed or there
are pressures that hamper the
smooth evacuation of fumes
1. Combustion wrong
2. Flame oxygen de cient
Any
kind
of
tampering
substitution of non-original of the thermostove
can be hazardous to the safety of the operator
and relieves the manufacturer from any civil or
criminal liability. Use only original spare parts.
Replace a worn before failure promotes the
prevention of injuries resulting from accidents
caused by the sudden failure of the components.
Follow
carefully
cleaning instructions. Failure to
follow these instructions could
create problems with the operation
of the thermostove.
After
1300
tion
of
pear on the lower display the
word
"SE RV",
Authorized Service Center for cleaning and
routine maintenance.
REMEDY
1. De ne the adjustment of the stove
2. Clean the smoke duct and check the pressure
switch that measures the proper depression of
the chimney
1. De ne the adjustment of the stove
2. Make sure the air duct up to the brazier is not
obstructed
3. Contact your Authorized Assistance Center
or
unauthorized
the
following
hours
of
opera-
the
heater
will
please
contact
ap-
your