Connection to the ue pipe
The ue pipe must have internal dimensions not
larger than 20x20 cm, or diameter 20 cm. In the
event of larger dimensions, or of the ue pipe
being in poor condition ( for example cracks,
poor insulation, etc.), it is advisable to
stainless steel pipe of suitable diameter inside
the ue pipe throughout its length, right up to
the top. Check with suitable instruments that
there is a draught between 4 Pa and 10 Pa. This
type of connection ensures the evacuation of the
fumes even in the event of a temporary power
cut. At the bottom of the ue pipe, provide an
inspection cap to allow periodic checking and
cleaning, which must be done annually. Make
a gas-tight connection to the ue pipe, using
pipes and connectors as recommended by us.
You must ensure that a windproof cowl should
be tted which complies with the standards in
force.
Connection to an external ue with insulated
or double-wall pipe
The only type of pipe which is permissible is
insulated (double-walled) stainless steel, smooth
on the inside, xed to the wall. Flexible stainless
steel pipe must not be used. At the bottom of
the ue pipe, provide an inspection cap to allow
periodic checking and cleaning, which must be
done annually. Make a gas-tight connection to
the ue pipe, using pipes and connectors as
recommended by us. You must ensure that a
windproof cowl should be tted which complies
with the standards in force. Check with suitable
instruments that there is a draught between 4 Pa
and 10 Pa.
Connection to the ue pipe
For proper functioning, the connecting pipe
between the stove and the chimney or ue duct
must have a slope of not less than 3% in the
horizontal stretches, the length of which must
not exceed 2 metres and the vertical distance
between one tee connector and another (change
of direction) must not be less than 1,5 m. Check
with suitable instruments that there is a draught
between 4 Pa and 10 Pa. At the botton of the
ue pipe, provide an inspection cap to allow
periodic checking and cleaning, which must be
done annually. Make a gas-tight connection to
the ue pipe, using pipes and connectors as
recommended by us. You must ensure that a
windproof cowl should be tted which complies
with the standards in force.
t a
Fig. 2: connection to the
ue pipe.
Fig. 3: connection to an
external ue with insulated
or double-wall pipe.
65