Servicing The Fluid Section; Repacking The Fluid Section - Titan 440 Manual Del Propietário

Ocultar thumbs Ver también para 440:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Servicing the Fluid Section

Use the following procedures to service the valves and repack
the fluid section. Perform the following steps before performing
any maintenance on the fluid section.
1. Loosen and remove the four front cover screws. Remove
the front cover.
2. Stop the sprayer at the bottom of its stroke so that the
piston is in its lowest position.
3. Perform the Pressure Relief Procedure and unplug the
sprayer.
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. always unplug the sprayer
before servicing!
4. Unscrew the return hose assembly from the pump block.
Remove the retaining clip from the bottom of the foot valve
housing. Remove the siphon assembly.
5. Tilt the sprayer back for easy access to the fluid section.
Servicing the valves
The design of the fluid section allows
access to the foot valve and seat
as well as the outlet valve and seat
without completely disassembling
the fluid section. It is possible that
the valves may not seat properly
because of debris stuck in the foot
valve seat or outlet valve seat. Use
the following instructions to clean the
valves and reverse or replace the
seats.
1. Remove the pusher stem clip
and slide the pusher stem
housing from the foot valve
housing.
2. Using a wrench, loosen and
remove the foot valve housing
from the pump block.
3. Clean out any debris in
the foot valve housing and
examine the valve housing and seat. If the seat is
damaged, reverse or replace the seat.
4. Using a 5/16" hex wrench, loosen and remove the outlet
valve retainer from the piston rod.
NOTE: always service the outlet
valve with the piston rod
attached to the pump.
This will prevent the
piston rod from rotating
during disassembly of
the outlet valve.
5. Clean out any debris and examine
the outlet valve housing and seat.
If the seat is damaged, reverse or
replace the seat.
6. Remove, clean, and inspect the outlet cage, crush
washer, and outlet valve ball. Replace if they are worn or
damaged.
NOTE: The outlet cage always must be used with the
crush washer. They are included together in the
repacking kit as assembly P/N 704-642.
7. Reassemble the valves by reversing the steps above.
© Titan Tool Inc. All rights reserved.
NOTE: During reassembly of the outlet valve, apply one
drop of Loctite (included in the repacking kit) to
the threads of the outlet valve retainer before
threading it into the piston rod. Then, torque the
retainer to 144 in./lbs. (12 ft./lbs.).

Repacking the Fluid Section

1. Remove the foot valve assembly using the steps in the
"Servicing the Valves" procedure above.
NOTE: The outlet valve does not need to be
disassembled from the piston rod for this
procedure.
2. Using 3/8" a hex
wrench, loosen and
remove the two pump
block mounting screws.
3. Pull the pump block
down approximately 1/2"
from the pump housing.
4. Slide the pump block
Pump
and piston rod forward
block
until the piston rod is out
Bushing
of the T-slot on the slider
assembly.
Foot valve
5. Slide the piston rod out
seal
through the bottom of
Inlet cage
the pump block.
Foot valve
6. Loosen and remove the
ball
retainer nut and piston
Foot valve
guide from the pump
seat
block.
Teflon
7. Remove the upper and
O-ring
lower packings from the
Foot valve
pump block.
8. Clean the pump block
O-ring
and install the new upper and lower packings. Refer to
the illustration below for proper packing orientation.
Pusher
stem
Install upper packing
housing
with raised lip and O-ring
Raised Lip
Piston rod
9. Inspect the piston rod for wear and replace if necessary.
Outlet cage
10. Reassemble the outlet valve assembly into the piston
Crush
rod. Tighten the outlet valve retainer with a wrench until
washer
secure.
Outlet valve
ball
NOTE: use the T-slot on the slider assembly to hold the
Outlet valve
piston rod in position while securing the outlet
seat
valve retainer.
Outlet valve
retainer
IMPORTaNT: Never use a wrench on the piston itself. This
could cause damage to the piston and cause leakage.
11. Insert the piston guide into the retainer nut. Thread the
retainer nut into the pump block until it is hand tight.
12. Slide the piston guide tool (included in the repacking kit)
over the top of the piston rod and insert the piston rod
through the bottom of the pump block. Using a rubber
mallet, tap the bottom of the piston rod lightly until the
piston rod is in position in the pump block.
11
T-Slot
Install lower packing
with the beveled
facing down.
edge facing up.
O-Ring
English
Slider
assembly
Retainer
nut
Piston
guide
Upper
packing
Pump
block
Pump block
mounting
screw
Lower
packing
Piston rod
Beveled Edge

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido