General Information; Environmental Conditions; Temperature; Delivery Configuration - Metrix MX 655 Manual De Instrucciones

Pinza multímetrica
Ocultar thumbs Ver también para MX 655:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

5.4. General information

Digital display
3 ¾ digit LCD with max. reading of 3,999 counts
Analogue display
42-segment bargraph
Polarity
When a negative signal is applied, the
Low battery indicator
is displayed when the voltage supplied by the batteries is
lower than the operating voltage. Measurements are no longer
guaranteed.
Power supply
Battery: 9 V, NEDA 1604 , 6F22, 006P or alkaline
Typical autonomy: 180 hours (MX 650)
36 hours (MX 655)
with alkaline battery and without buzzer function.
Protection level of the housing
IP30 according to NF EN 60529 Ed. 92
Maximum jaw opening
∅ 36 mm
MX 650:
∅ 40 mm
MX 655:
Dimensions
246 x 93 x 43 mm
Weight
400 g (with battery)

5.5. Environmental conditions

5.5.1.

Temperature

Operation:
0°C to 40°C, < 70 % RH
Storage:
-10°C to 60°C, < 80 % RH
5.5.2.
E.M.C.
Immunity:
in accordance with EN 50081-1 Ed.95
Emission:
in accordance with EN 50082-2 Ed.95

5.6. Delivery configuration

Instrument delivered with:
1 set of measuring leads (one black, one red)
1 x 9 V alkaline battery
1 carrying case
1 user's manual
1 verification certificate
APPENDIX: Reference conditions
Sine signal:
- Frequency from 48 to 65 Hz
- No continuous components
Temperature 23°C ± 5°C
External magnetic field < 40 A/m
No alternating magnetic field
Measured conductor centred (in A)
30
Chapter II
signal appears.
MX 650 / MX 655

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mx 650

Tabla de contenido