Kohler CORALAIS K-15290 Instrucciones De Instalación página 3

Grifo de bañera montado en la bañera / cubierta
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

NOTE: This frame applicable to rough (unfinished) deck
installations only.
Set Valve Body Height: Use one of the following two
formulas to calculate the valve body clearance required
for the finish material at your installation.
If tile to be installed measures less than 1" (2.5cm) thick,
add that measurement to 1-1/4" (3.2cm).
Example #1: Tile thickness (3/4" (1.9cm)) + 1-1/4" (3.2cm)
= 2" (5.1cm) clearance.
If the tile to be installed measures between 1" (2.5cm) and
1-1/4" (3.2cm) thick, add only 1" (2.5cm) to 1-1/4" (3.2cm).
Example #2: Tile thickness (1-1/8" (2.9cm)) =1" (2.5cm)
+ 1-1/4" (3.2cm) = 2-1/4" (5.7cm) clearance.
Adjust threaded collar until the dimension from the top of
the sleeve to the top of the rough deck surface equals the
clearance requirement you calculated.
Note this dimension. You will need to use it again after
connecting the supply tube.
NOTE: This frame applicable to rough (unfinished) deck
installations only.
Supply Tube Connection: Measure distance from
bottom of spout supply tube to top of tee.
Add 1" (2.5cm) to this measurement and cut a piece of
1/2" nominal (5/8" O.D.) copper tubing to fit into the supply
tube and tee port.
NOTE: This frame applicable to rough (unfinished) deck
installations only.
Back off threaded collars as far as possible without
removing them. Pivot the valve bodies enough to remove
the tee and two pieces of tubing. (If valve body holes are
smaller than recommended, it may be necessary to
remove the entire valve body assembly.)
Install tubing into tee. Mate copper tube from tee with
spout supply tube. Pivot the valve bodies onto the two
pieces of copper tubing.
Do not solder at this time.
Kohler Co., Kohler, WI U.S.A.
Top Of Sleeve
1-1/4"(3.2cm)
2" (5.1cm)
À À À À À
Clearance
À À À À À
É É É É É
3/4" (1.9cm)
É É É É É
2-1/8"
É É É É É
(5.4cm)
Max.
Top Of Sleeve
1-1/4" (3.2cm)
2-1/4" (5.7cm)
À À À À À
Clearance
É É É É É
À À À À À
1-1/8" (2.9cm)
É É É É É
2-1/8"
(5.4cm)
Max.
Sleeve
Threaded
Collar
Rough
Deck
Mounting
Nut
Copper
Tube
3
Tile Thickness
Threaded Collar
Rough Deck
EXAMPLE #1
Tile Thickness
Threaded
Collar
Rough Deck
EXAMPLE #2
Fig. #5
Spout Supply Tube
Measure
Distance
Tee
Fig. #6
Spout Supply
Tube
Tee
Fig. #7
1012829-2-
B

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Coralais k-15290mCoralais k-15294Coralais k-15294m

Tabla de contenido