Specifications; Leak Check Procedure - Jetboil STASH Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27

SPECIFICATIONS

Gas category: Direct Pressure – Butane-Propane
mixture. This appliance shall only be used with
a Jetboil Jetpower 75%/25% Isobutane/Propane
Mix Fuel Canister (sold separately) conforming
to EN417 or AS2278. It may be hazardous to
attempt to fit other types of gas containers.
Jet Size: 0.21mm Gas Consumption: 5 MJ/hr (AU) ||
108 g/hr [1.52 kW] (EU) || 4,500 BTU/hr (CA)
LEAK CHECK
PROCEDURE
1. Perform leak checks outside, in a well-ventilated
area.
2. Connect fuel canister (3.1) to valve (3.2) by threading
in the orientation shown in Fig 4.
3. Put soapy water on the gas connection between fuel
canister and the valve. Formation of bubbles indicate
a gas leakage.
Do not check for leaks using a flame.
WARNING
If a leak is detected, do not attempt ignition.
WARNING
4. Remove fuel canister immediately and contact
Customer Service.
5. If no leak is found, detach fuel canister.
Leak check is complete.
4

Publicidad

Tabla de contenido
loading

Tabla de contenido