The device is configured with the ETS software, to perform the following functions:
Temperature control
• at 2 points, with ON/OFF commands or 0%/100% commands
• integral proportional control, with PWM commands or continuous adjustment (0% - 100%)
Fan coil management
• control of fan coil speed, with ON/OFF selection commands or continuous adjustment (0% -
100%)
• management of 2-way or 4-way systems, with ON/OFF commands or 0%/100% commands
Operating mode setting
• from the BUS, with distinct 1-bit objects (OFF, ECONOMY, PRE-COMFORT, COMFORT)
• from the BUS, with a 1-byte object
Temperature measurement
• with a built-in sensor
• mixed built-in sensor / KNX temperature adjustment probe / external temperature sensor
with definition of the relative weight
Underfloor probe
• setting of threshold value for floor temperature alarm
Temperature control for specific zones
In "Master" control mode:
• with transmission of the operating mode towards Slave thermostats
• with transmission of the Setpoint towards Slave devices
In "autonomous" control mode:
• with local selection of operating mode and Setpoints
Scenes
• storage and activation of 8 scenes (value 0..63)
Hourly profiles
• programming on a weekly basis, with a 7 day program and hourly profiles that can be
independently configured for each day
• the possibility to set up to 12 hourly profiles 2 for use as a timed thermostat, and 10 for use
as an hourly programmer; the profiles can be attributed to temperature adjustment or another
communication object
• the possibility to pre-set hourly profiles directly from ETS, with a limit of 4 daily switchovers;
the profiles can be attributed to temperature adjustment or another communication object.
Other functions
• setting of the Setpoint (OFF, ECONOMY, PRE-COMFORT, COMFORT) from the BUS
• setting of the type of operation (heating / air-conditioning) from the BUS
• transmission of the status information (mode, type), measured temperature and current
Setpoint on the BUS
• setting of the date and time from the BUS
• transmission of the date and time on the BUS
• management of the status information arriving from the commanded actuator
• management of the status signalling for temporarily switching off the timed thermostat
• auxiliary input for fronts management, brief/prolonged operation, dimmer with single push-
button, roller shutters with single push-button, scenes and window contact
GENERAL DESCRIPTION
GENERAL DESCRIPTION
18