Use of Ø50 and Ø60 flexible pipe (for ducting only)
The chart includes the starting accessories code 041087X0 for Ø50 and code 041050X0 for Ø60.
Up to 4 m. of Ø80 mm flue can be used between the boiler and the passage with reduced width (Ø50 or Ø60), and up
to 4 m. of Ø80 mm flue on the intake (with max. length of Ø50 and Ø60 flues).
max 4 m
Ø80
To use this width, follow the instructions below.
Enter the menu SC (follow the instructions given in par. "Combustion Control Menu" on page 210) and set the parameter
SC04 to the value corresponding to the length of flue used.
For model BLUEHELIX MAXIMA 24C/
For model BLUEHELIX MAXIMA 34C
SC04
13
12
10
8
6
4
2
0
0
10
200
max 4 m
Ø80
fig. 19
20
30
40
fig. 20- Chart for flue parameter choice
cod. 3541U630 - Rev. 00 - 07/2020
BLUEHELIX MAXIMA
A =
BLUEHELIX MAXIMA 24C
Ø50 - 28 m MAX
Ø60 - 78 m MAX
BLUEHELIX MAXIMA 28C
Ø50 - 22 m MAX
Ø60 - 60 m MAX
BLUEHELIX MAXIMA 34C
Ø50 - 17 m MAX
Ø60 - 45 m MAX
For model BLUEHELIX MAXIMA 28C/
50
60
70
m
80
EN