BLUEHELIX MAXIMA
System diagnostics
The values of the sensors and actuators in the boiler are available.
Note: To return to the Service Menu, touch the arrow at the top left of the screen
Description
Combustion
Burner power
Flame status
Fan rpm
Operating hours
Fume Temperature
Hydraulics
Heating Flow
Heating Return
NTC DHW sensor (°C)
DHW draw-off
Modulating pump speed
System water pressure
Environment
External probe
Transparent Parameters "B" menu
By selecting a parameter on the screen, the possible values will be shown. If the values shown do not match
A
those indicated in the corresponding "Range" column, check that the parameter B01 is correctly set to RRT.
Code Description
B01 Boiler type selection
B02 Exchanger type
Absolute Maximum Heating
B03
Power
System water pressure pro-
B04
tection selection
B05 NOT IMPLEMENTED
Variable input contact ope-
B06
ration selection
B07 Relay card LC32 selection
EN
Range
00%=Min., 100%=Max.
00÷255
00÷120
00÷99
0÷125 °C
0÷125 °C
0÷125 °C
0÷125 °C
00÷99 L/min
00÷100%
00-9.9 bar with pressure transducer
+70 ÷ -30°C
Range
RRP (INSTANTANEOUS COMBI)
RRH (HEATING ONLY also with OPTIONAL HOT WATER STO-
RAGE TANK
RRT (COMBI HEATING ONLY)
RRK (HEATING ONLY with HOT WATER STORAGE TANK)
1 ÷ 4
0 ÷ 100% (Do not modify the value)
Pressure switch
Pressure Transducer
Flow meter exclusion
System thermostat
Second room therm.
Warning/Alert
Safety thermostat
External gas valve
Alarm
System filling solenoid valve
Solar 3-way valve
Second heating pump
Alarm2
Burner lit
Frost protection active
cod. 3541U630 - Rev. 00 - 07/2020
Default
RRT
BLUEHELIX MAXIMA 24C = 1
BLUEHELIX MAXIMA 28C = 2
BLUEHELIX MAXIMA 34C = 3
BLUEHELIX MAXIMA 24C = 75%
BLUEHELIX MAXIMA 28C = 85%
BLUEHELIX MAXIMA 34C = 85%
Pressure transducer
--
Second room thermostat
System filling solenoid valve
207