8. Technical data
SR-HPM-110-MT-
/SR-HPM-110-UN-
Measuring range
Overload pressure
Pmax
Burst pressure
Protection class
Input
Power supply
100
600
0...100
0...600
bar
bar
200
1,000
bar
bar
800
2,000
bar
bar
IP67, data logger version: IP65 (IEC 60529)
10-ms sample rate
Exactness:
0.5% FS ± 1 digit:
SR-HPM-110-MT-XXX
0.5% FS ± 1 digit:
SR-HPM-110-UN-XXXX
+ 0.2%/year
2 x 1.5 V (AA)
Battery life max. 1,500 h,
with data logger 600 h
Technical data
/1500
/8700
/0...1450
/0...8700
psi
psi
/2,900
/14,500
psi
psi
/11,600
/29,000
psi
psi
35