Descargar Imprimir esta página

Leuze electronic MLDSET-M1 Manual De Instrucciones página 14

Ocultar thumbs Ver también para MLDSET-M1:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 21
 Connect the connection cable (machine interface) to the safety sensor and
connect it to the machine control components as described in the original
operating instructions.
Pin assignment
Pin
Connection to MLD
1
24 V
2
MS2
3
0 V
4
MS1
5
RES/LMP
Step 5: Align and start up MLD530 muting transceiver
 Switch on the safety sensor.
 Adjust the height of the safety sensor and the Deflecting Mirror. After the
Allen screws are loosened
 Adjust the axial alignment of the safety sensor and the Deflecting Mirror.
After the Allen screws
built-in device can be rotated slightly.
Step 6: Align and start up muting sensor sets
A: Position the sensors/reflectors.
 Loosen the duct cover
 Position the sensors/reflectors by moving in the axial direction
 After aligning, retighten the Allen screw
 Cut the duct cover to the appropriate length and remount
B: Align the sensors and reflectors.
 Loosen the two Phillips screws
 Turn to set the correct angle of the sensors/reflectors
 After aligning, retighten the Phillips screws
 The optimal alignment has been achieved when the green LEDs on the
muting sensors illuminate!
Checklist – prior to the initial start-up
Step 7: Edit
 Start up the machine or system according to the original operating
instructions of the safety sensor.
Service hotline
You can find the contact information for the hotline in your country on our website
www.leuze.com under Contact & Support.
MS1
MS2
24 V
24 V
0 V
0 V
MS1
MS2
, the devices can be slid easily into the slot.
1
have been loosened, the entire column with the
2
and the Allen screw
1
.
4
LMP
24 V
RES/LMP
0 V
RES/LMP
.
2
.
2
.
5
.
4
EN
RES
24 V
RES/LMP
0 V
RES/LMP
.
3
.
1
14

Publicidad

loading

Este manual también es adecuado para:

Mldset-m2