The connection cables should obey MDL this table:
Model
Speci cation of connection cables
(mm2)
Indoor connection
Open the front panel, inset the connection cables from the base of the air-conditioner, conneting to the terminal board in order (according to
the graph), using the pressing board to fasten the connection cables.
Bottom frame
Connection cables
Bottom frame
Connection cables
Open the front panel, if the indoor unit is fi tted with the signal wire, please detach the mid-frame, and insert the signal wire through the bot-
tom frame, then connect the signal wire quick plug of the indoor's to the outdoor's.
Outdoor connection
 Unscrewthe screw, take off the control panel cover from the unit.
 According the connect position of indoor unit, make sure the connection cables connet to the board of outdoor unit corresponding.
 The grounded wire connection:
1. Loosen the grounded screw of electric bracket.
2. Connect the grounded wire with the grounded screw then setscrew in the «&» mark formerly.
 Fix the cable to the terminal board with pressing board.
 Reinstall the cover with the screw

ELECTRICAL CONNECTION

≤9000Btu
≤12000Btu
(≤2500W)
(≤3500W)
1,0
Wiring diagram of constant speed
Front panel
Connection cables
Mid-frame
Front panel
Connection cables
Mid-frame
14
≤18000Btu
(≤5100W)
1,5
1,5
Pressing
board
Pressing
board
≤24000Btu
(≤7200W)