SELECTION OF THE INSTALLING POSITION
Indoor Unit
There is no heating and steaming source nearby.
No obstacles for installing position nearly.
Keep good air circulation.
Convenient to adopt measures to reduce noises.
Do not install them near the doorway.
Make sure to have the distance between the ceiling, wall,
furniture and other obstacles.
2 meters high above the fl oor.
Outdoor Unit
In case that you put up a canopy to protect it from rains and sunrays, pay attention not
to cause any obstacles for the heating dispersion for the condenser.
Do not grow animals or plants near the installation location for the cold and hot air out
will aff ect them.
Make sure to have the distance specifi ed in the picture between ceiling, wall, furniture
and other obstacles.
Stay away from heating source and infl ammable air.
The installation base and supporting frame should be strong and secure. The machine
should be at plane surface.
The distance between indoor and outdoor unit should be 5 meters and pipe length can go up to maximum 15 meters with additional refrig-
erant charge.
Max. Allowable Tubing
Limit of Tubing Length(m)
Length at Shipment(m)
5
15
Above
15cm
Requires Amount of Additional
Limit of Elevation Di er-
Refrigerant (g/m)
ence H(m)
CC≤12000Btu
5
20
9
Above
15cm
CC≥18000Btu
30