Troubleshooting - Waeco MagicWatch MWE910 Instrucciones De Montaje Y De Uso

Ocultar thumbs Ver también para MagicWatch MWE910:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 41
All manuals and user guides at all-guides.com
MagicWatch MWE910
11

Troubleshooting

The device indicates no function.
The cables to the reversing light are not connected or are not properly con-
nected.
The plugs for the sensors are not connected or are not properly plugged into
the control electronics.
➤ Check the plugs, and make sure they lock into place.
Error tone for three seconds after engaging reverse gear
One or more sensors are defective or no longer connected to the control
electronics. The display shows the defective sensor:
for example E1 for front sensor with short cable or E5 for rear sensor with
short cable.
EE if more than one sensor is defective
➤ Check the plugs and make sure they lock into place.
➤ Replace the defective sensor(s).
Caution
a
The system does not work if one or more sensors are defective.
Device indicates obstacles incorrectly.
False alarms may have the following causes:
Dirt or frost on the sensors
➤ Clean the sensors.
The sensors were incorrectly installed.
➤ Adjust the position or height of the sensors (fig. 3).
The sensors have contact with the chassis.
➤ Disconnect the sensors from the chassis.
Troubleshooting
23

Publicidad

Tabla de contenido
loading

Tabla de contenido