Half mask without inhalation valve with particle filter EN 
 
 Before using the product, read these instructions carefully. 
 Scrupulously follow the indications given in this instruction leaflet. The devices that 
are  described  must  only  be  used  in  compliance  with  these  instructions,  with  the 
described  configurations  and  specified  use.  An  incorrect  and  non‐conforming  use 
with respect to the instructions could cause a serious hazard.  
 The user must fully understand the instructions and follow them at all times: before 
using the product, the user must decide whether it is suitable for the planned use. 
 The instructions must always be kept with the product. Ensure they are well conserved 
and available for users. 
 Breathing devices must only be used by expert, trained staff under the supervision and 
responsibility of people who are perfectly aware of the application limitations to the 
equipment and of the laws in force in the country where the equipment is used. 
 Maintenance  and  any  repairs  to  the  device  must  only  be  carried  out  by  expert, 
trained staff. SPASCIANI S.p.A. accepts no liability for damage caused further to an 
incorrect or inappropriate use of the PPE, or due to maintenance or repairs that are 
not carried out on the premises of SPASCIANI S.p.A. or their expressly authorized 
service centres. 
 Only use original SPASCIANI S.p.A. components and accessories for the maintenance work. 
 Do not use any devices which show signs of damage, defects or being incomplete 
when they are to be used. Do not make any alterations to the device. 
 
1. DESCRIPTION 
The M 900 P3 particle respirator is certified according to the EN 1827:1999+A1:2009 
standard,  with  the  following  designation:  half‐mask  without  inhalation  valve  EN 
1827:1999 FM P3 NR.  
The half‐mask is formed of: 
Moulded anatomical silicone half‐mask, with a specific plug‐in connection to house 
the filter and with an exhalation valve protected by a cover. 
Silicone harness with a 2‐point connection and fast adjustment buckle. 
M 900 FM P3 NR particle filter, firmly tightened inside the half‐mask. 
2. DESIGNED USE 
Spasciani's M 900 P3 half‐mask with particle filter offers protection from dust, smoke 
and mist in the air inhaled by the user, and it can only be used once.  
Using the device is subject to the correct maintenance and replacement of the filter. 
It does not protect from Carbon Monoxide! 
3. LIMITATIONS TO USE 
Only use if the surrounding air has an oxygen volume concentration between 17 and 
21% (or as specified in current national laws). 
Do not use in oxygen enriched atmospheres. 
   
 
 
 
 
 
EN      RESPIRATOR M 900 P3  
1827 FM P3 NR 
 
 
 
 
 
 
 
 
 
CAUTION 
 
 
 
 
 
 
 
 
 
 
 
Pg. 6/32 