Always remove the battery before carrying out any work on the power tool.
Condition
Running time is too short
Battery jams when being inserted in power
tool / charger
Battery is not charge even though the light
emitting diode on the charge lights up green
Light emitting diode on charge flashes red
1)
STIHL recommends a STIHL servicing dealer.
HSA 65, HSA 85
Cause
Battery is not fully charged
Life of battery has been reached or
exceeded
Blades sticking / dirty
Guides dirty
Battery too hot / too cold
(1 light emitting diode on battery lights
up red)
No electrical contact between charger
and battery
Battery faulty
(4 light emitting diodes on battery flash
red for about 5 seconds)
Charger faulty
Remedy
Charge the battery
1)
Check battery
and replace
Clean the blades and spray them with
STIHL resin solvent
Carefully clean the guides
Allow battery to cool down / warm up
Operate the charger indoors only in dry
locations at an ambient temperature
between +5°C and +40°C.
Remove the battery and refit it properly
1)
Install new battery
Have charger checked by servicing
1)
dealer
English
49