Status Indication - 3M DBI SALA NANO-LOCK 3100273 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.0
USE
;
Avoid close proximity of the Connected Aluminum Carabiner with implanted medical devices. Connected Carabiners contain
magnets and Bluetooth capabilities. Contact your medical device manufacturer regarding safe operation of the system.
4.1
BEFORE EACH USE: Verify that your work area and Fall Arrest system meet all criteria defined in Section 2. Verify that a
formal Rescue Plan is in place. Inspect the Connected Order Picker System per the 'User' inspection points defined on the
"Inspection and Maintenance Log". If inspection reveals an unsafe or defective condition, or if there is any doubt about its
condition for safe use, remove the system from service immediately. Clearly tag the system "DO NOT USE". See Section 5
for more information.
4.2
SYSTEM APPLICATIONS: The Connected Order Picker System is designed for use in Fall Arrest applications as
described in these instructions. Use with any other system application is prohibited.
4.3
BLUETOOTH PAIRING: The Carabiner and Sensor Box are paired at the factory and will be ready for operation with the
Connected Order Picker System. See Figure 11 for reference. To pair the Sensor Box with the Carabiner:
1.
Press and hold for two seconds the pairing button (D) on the side of the Sensor Box. This will put the Sensor Box into
pairing mode, during which a blue wave pattern will display on the Feedback Lights.
2.
Open and close the gate lock of the Carabiner five times within a two-second period. To open and close the gate lock,
rotate the gate back and forth (A). This will put the Carabiner into pairing mode.
3.
A successful pairing will be indicated by a green confirmation pattern on the Feedback Lights and an audible chirp
from the Sensor Box.
4.
If a pairing failure occurs, repeat the pairing procedure. Pairing failure is often caused by the gate lock actions not
being completed within the two-second timeframe. If pairing failure continues to happen, check the battery of the
Carabiner.
;
A pairing failure is indicated by a short, flashing yellow pattern on the Feedback Lights and a descending pair
of tones from the Sensor Box. A pairing failure will occur if the Sensor Box does not detect the Carabiner within 30
seconds.
4.4
SYSTEM PLACEMENT: The SRD should be positioned directly above the user. The Sensor Box should be positioned
directly above the center of the order picker platform. Placement of the Sensor Box should cover as much of the standing
area as possible. See Figure 12 for reference. The sensors (A) should be unobstructed and should have a clear view of the
center of the platform.
4.5
USER INTERFACE: The Connected Order Picker System relies on the Feedback Lights and Sensor Box to indicate the
tie-off status of the user. The Sensor Box and Carabiner collect information via electronic sensors and then relay this
information back to the user through the system. Different blink patterns and sounds emitting from the system will
indicate different situations to the user:
Reason
Tie-Off Alert
Tie-Off Confirmation
System Power Up
Low Battery - Carabiner
Bluetooth Pairing
No Bluetooth Connection
Hard Fault on Sensor Box
Hard Fault on Carabiner
4.6
BATTERY REPLACEMENT: The battery of the Connected Carabiner should be replaced whenever a 'Low Battery' status
is indicated by the user interface of the Connected Order Picker System. See Table 1 for a list of compatible batteries.
;
Use only batteries specified in these instructions. Use of any other battery may present a risk of fire or explosion.
Occurs When...
User is within the detection radius of the Sensor Box
but is not tied-off to the Carabiner.
User connects the Carabiner to the D-ring of their
Full Body Harness.
The Sensor Box is supplied with electrical power.
User is within the detection radius of the Sensor Box
but is not tied-off to the Carabiner, and the Carabiner
is reporting a 'Low Battery' status.
System is in Bluetooth pairing mode, due to a press
and hold of the pairing button on the Sensor Box.
User is within the detection radius of the Sensor Box,
but no communication is coming from the Carabiner.
A hardware failure is detected at power up on the
Sensor Box. The Sensor Box should be serviced.
User is within the detection radius of the Sensor Box,
but is not tied-off to the Carabiner and the Carabiner
is reporting a hardware failure. The Carabiner should
be serviced.

Status Indication

Stage of alert patterns, escalating with time until the
user completes tie-off:
• First: Feedback Lights emit constant red glow.
• Second: Feedback Lights pulse red.
• Third: Feedback Lights flash brighter red and
Sensor Box chirps audible alert tone.
Green blink of the Feedback Lights.
Red, green, and blue chase pattern on Feedback
Lights, with an audible chirp from the Sensor Box. If
the Sensor Box detects a self-test failure, it will play
a series of descending tones instead of a chirp.
Escalating alert pattern (as seen in 'Tie-Off Alert'),
but with the top and bottom portions of the Feedback
Lights displaying yellow instead of red.
Blue wave pattern on the Feedback Lights. See
Section 4.3 for more information.
Escalating alert pattern (as seen in 'Tie-Off Alert'),
but with the top and bottom portions of the Feedback
Lights displaying blue instead of red.
Short yellow blink once every three seconds.
Escalating alert pattern (as seen in 'Tie-Off Alert'),
but with the top and bottom portions of the Feedback
Lights displaying violet instead of red.
15