SCS Sentinel HWay Instrucciones De Uso E Instalación página 38

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

There actions of
photocell/ safety
3
edge/ loop de-
tector when they
detecting
3.1 : Input PH1 active only at closing (total reopening in case of passage during the closing)
Input PH2 active only at opening (total reclosing in case of passage during the opening)
3.2 : Input PH1 active only at closing (total reopening in case of passage during the closing)
Input PH2 active at opening and closing (direction changing during 2 seconds if the gate is moving)
3.3 : Input PH1 active only at closing (total reopening in case of passage during the closing)
Input PH2 active only at closing (total reopening in case of passage during the closing).
Closed and stopped gate, a passage triggers the opening (total)
4
Motor speed
The deceleration
5
setting for gate
moving
Deceleration
6
speed
(% full speed)
7
Force of motor
Open partially
8
(pedestrian
opening)
38
EN
3-1
3-2
See below
3-3
4-1
Slow
4-2
Middle
4-3
Fast
4-4
Very fast
5-1
75% of full distance
5-2
80%
5-3
85%
5-4
90%
5-5
95%
6-1
80%
6-2
60%
6-3
40%
6-4
25%
7-1
2A
7-2
3A
7-3
4A
7-4
5A
7-5
6A
7-6
7A
8-1
10%
8-2
20%
8-3
30%
8-4
40%
8-5
50%
8-6
60%
Please do the function setting after
H&J
The factory setting is « 3-1 »
The factory setting is « 4-3 »
The factory setting is « 5-1 »
The factory setting is « 6-3 »
The function can adjust the running
force of motor to be compatible with
the gate weight.
The factory setting is « 7-5 »
This function can adjust the width of
opening partially.
The factory setting is « 8-2 »

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mco0093

Tabla de contenido