SCS Sentinel HWay Instrucciones De Uso E Instalación página 39

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9
Pre-Flashing
Over current
A
reverse setting
Full open remote
switch
C
(on the remote
control)
Pedestrian open
remote switch
E
(on the remote
control)
External device
control function
F
key (on the remote
control)
Photocells 1
H
function
Photocells 2
J
function
L
Stop command
Remote control
P
function
The flashing light
9-0
blinks when the
gate starts to move
The flashing light
blinks 3 seconds
9-1
before the gate
starts to move
A-0
Stop
A-1
Reverse 1 second
A-2
Reverse 3 seconds
A-3
Reverse to the end
C-1
the top left button
C-2
the top right button
the bottom left
C-3
button
the bottom right
C-4
button
No function in
E-0
transmitter
E-1
the top left button
E-2
the top right button
the bottom left
E-3
button
the bottom right
E-4
button
No function in
F-0
transmitter
F-1
the top left button
F-2
the top right button
the bottom left
F-3
button
the bottom right
F-4
button
H-0
Stand-by
H-1
Ready
J-0
Stand-by
J-1
Ready
L-0
Close
L-1
Open
P-1
Close
P-2
Open
The factory setting is « 9-0 »
The factory setting is « A-3 » .
The reverse function only operates 3
times and then stops.
If gate reverses, the auto close
function will be cancelled.
The factory setting is « C-1 » .
The factory setting is « E-2 »
The factory setting is « F-3 »
The factory setting is « H-0 »
The factory setting is « J-0 »
The factory setting is « L-0 »
Exit 11 and 12
The factory setting is « P-1 »
EN
39

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mco0093

Tabla de contenido