Continuity Check
Do not connect the meter to a source of voltage or current when the
range selector is in the
Failure to observe this warning may result in serious injury or death.
Do not change the position of the selector switch when the test leads
are connected to a component or circuit. Damage to the meter can
result.
1. Shut off and disconnect the power. Make sure all capacitors are discharged. Voltage must
not be present.
2. Plug the black test lead into the COM input terminal, and plug the red test lead into the
Ω
V/
input terminal.
3. Set selector switch to the
4. Touch the test leads to the circuit under test.
5. The buzzer will sound continuously if the resistance of the circuit is lower than approxi-
mately 100Ω.
Note: The display will not correspond to the circuit resistance.
12
All manuals and user guides at all-guides.com
position. Electric shock can result.
position.