Descargar Imprimir esta página

External Input; Ventilation Setting; Flap Control; Auto-Restart - Mitsubishi Heavy Industries eco touch RC-EX1A Manual De Instalación

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 144

⑰ External input

⑱ Ventilation setting

⑲ Flap control

⑳ Auto-restart

All manuals and user guides at all-guides.com
⑰ External input
Set the range to apply the external input received through CNT of either one IU
to plural indoor units connected in one system
Individual: This is applied only to the IU receiving CNT input.
All units: This is applied to all indoor units connected.
⑱ Ventilation setting
Set this when a ventilation device is connected.
Disable: No ventilation device is connected.
Interlocking: Ventilation is interlocked with the Run/Stop of air conditioner.
Independent: If the ventilation is selected from the menu, only the
ventilation device is operated or stopped independently.
⑲ Flap control
Set the flap stop control.
Stop at fixed position: The flap can be set to stop at one of 4 positions.
Stop at any position: The flap can be set to stop at any position
⑳ Auto-restart
Set the state of operation to be started when the power supply is restored
after a power failure.
Enable: It returns to the state before the power failure as soon as the
power supply is restored (After the end of the primary control at
the power on).
Disable: It stops after the restoration of power supply, regardless the state
of operation before the power failure.
— 24 —
immediately after operating the R/C switch.

Publicidad

loading

Este manual también es adecuado para:

Eco touch rc-ex1n