pg9 cable glands provided must have
an outside diameter between 4.5 and
7 mm. The internal conductor wires
must have a nominal cross-section
of 0.75mm2. If a raceway is not used,
use H05RR-F cables. Pay careful at-
tention when fastening the cables
so that they are anchored in a stable
manner.
Furthermore, care is required when
drilling holes in the outside casing
where connecting and power sup-
ply cables will pass, and when as-
sembling the cable glands, so that
everything is installed so as to main-
tain the panel's IP protection cha-
racteristics.
9) The gear motor used to move the
fixture must comply with the require-
ments of point 5.2.7 of EN 12453.
10) In compliance with 5.4.2 of EN 12453,
it is recommended to use gear motors
equipped with an electrical-mechani-
cal release device, so that the fixture
can be moved manually in case of ne-
cessity.
11) In compliance with 5.4.3. of EN 12453,
use electrical-mechanical release sy-
stems or similar devices which stop the
fixture safely in the end run position.
12) The various electrical components
external to the control unit must be
wired in accordance with standard
EN 60204-1 as amended, and as set
forth in point 5.2.7 of EN 12453. The
fixing of power and connection cables
must be secured through the use of
cable glands.
13) The assembly of a push button panel
for manual control must be comple-
12