ted positioning the push button panel
in such a way that the user is not pla-
ced in a dangerous position.
14) The safety function ensured by the
control unit is active only during clo-
sing, therefore, protection on opening
must be ensured in the installation
phase with measures (guards or sa-
fety distances) independent from the
control circuit.
15) For proper functioning of the radio
receiver, if using one or more control
units, the installation at a minimum
distance of at least 3 metres one from
the other is recommended.
The electronic control unit:
LG 2329 - LRS 2329
LRS 2329 SET - LRH 2329
they comply with the specifications of the Directives
RED 2014/53/EU, EMC 2014/30/EU, LVD 2014/35/EU.
The full text regarding the EU Declaration of Conformity is available
from the following Internet address: http://www.seav.it
TECHNICAL DATA:
- Power supply
- Flashing light output
- Motor output
- Services power supply output
- Safety devices and controls in BT
- Operating temperature
- Radio receiver
- Op. transmitters
- No. of devices that can be stored
- Board dimensions
- Dimensions of container
- Container
TERMINAL BOARD CONNECTIONS:
CN1:
1 : 230 Vac line input (Phase)
2 : 230 Vac line input (Neutral)
3 : Opening 230V Motor Output
4 : Common 230V Motor Output
5 : Closing 230V Motor Output
6 : 230 Vac Flashing light Output (Neutral)
7 : 230 Vac Flashing light Output (Phase)
CN2:
8 : Power supply to photocells (12 Vac)
9 : Power supply to photocells (GND)
10 : Safety device input (NC)
11 : Common GND input
12 : Control button input (NA)
13
: 230 Vac 50-60Hz 900W (4A) max.
: 230 Vac 50-60 Hz
100W Resistive Load max.
50W Inductive Load max.
: 230 Vac 50-60Hz 750 W max.
: 12 Vac 2 W max.
: 12 Vcc
: -10 ÷ 55 °C
: see model
: 12-18 Bit - Rolling Code - Plus
: 120 max.
: 100x105 mm.
: 110x121x47 mm.
: ABS V-0 ( IP54 ).