FLAEM NebulFlaem 4.0 CONDOR F2000 Manual De Instrucciones página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
USE OF NEBULIZATION MANUAL CONTROL
To achieve continuous nebulisation action you should not use the manual nebulisation control (C6), especially in the
case of children or persons with reduced physical, sensory, or mental capabilities. The manual nebulisation control is
useful for limiting dispersion of the medication in the surrounding environment.
To start nebulizing close with a finger the
hole of the nebulizer manual control (C11)
and breathe in gently; we recommend to
hold your breath for a moment so that the
inhaled aerosol droplets can be deposited,
SOFTTOUCH FACE MASKS
Soft biocom-
patible
material
Dispersion
Limiting Vent
During inspiration the vent bends inwards.
CLEANING, SANITISATION, DISINFECTION, STERILISATION
Switch off the device before any cleaning procedure and unplug the power cable from the socket.
DEVICE (A) AND TUBING EXTERIOR (B)
Use only a damp cloth with antibacterial soap (non-abrasive and with no solvents of any sort).
ACCESSORIES
To disassemble the RF9 nebulizer.
Firmly grasp the bowl body and then use your other hand to rotate the particle size regulator (C1.1) clockwise until it
is ejected from the upper part (C1.2) as a result of unscrewing. The components can then be disassembled (regulator
C1.1a, valve C1.1b, selector C1.1c and upper part C1.2) to be cleaned. The nozzle (C1.3) is interference fitted in the upper
part (C1.2) and can be extracted by simply pulling it outwards.
Then proceed according to the instructions below.
CLEANING AT HOME - SANITISATION AND DISINFECTION
SANITISATION
Before and after each use, sanitise the cup and the accessories, choosing one of the methods described below.
method A: Sanitise accessories C1.1a-C1.1b-C1.1c-C1.2-C1.3-C1.4-C2-C3-C4-C5-C6 under potable hot water
(approximately 40°C) with a gentle, non abrasive dish detergent.
method B: Sanitise accessories C1.1a-C1.1b-C1.1c-C1.2-C1.3-C1.4-C2-C3-C4-C5-C6 in the dishwasher with a hot
cycle.
method C: Sanitise accessories C1.1a-C1.1b-C1.1c-C1.2-C1.3-C1.4-C2-C3-C4-C5-C6 by immersing them in a solution
of 50% water and 50% white vinegar, then rinse thoroughly under potable hot water (approximately 40°C).
If you want to also perform the cleaning for DISINFECTION, jump to the DISINFECTION paragraph.
After having sanitised the accessories, shake them vigorously and place them on a paper towel. Alternatively, dry
them with a jet of hot air (for example, a hair dryer).
DISINFECTION
After sanitising the cup and the accessories, disinfect them choosing one of the methods described below.
method A: Accessories C1.1a-C1.1b-C1.1c-C1.2-C1.3-C1.4-C2-C3-C4-C5-C6 can be disinfected.
The disinfectant must be an electrolytic chloroxidizer (active principle: sodium hypochlorite) specific for disinfecting,
which is available in any pharmacy.
Implementation:
- Fill a container big enough to hold all of the parts to disinfect with a solution of potable water and disinfectant,
according to the proportions indicated on the packaging of the disinfectant.
The new SoftTouch Masks feature an adaptive edge made of a soft biocompatible
material ensuring an excellent adherence to the face and a Dispersion Limiting Vent.
These innovations, which make them stand out from the rest, allow increased
sedimentation of medication in the lungs and reduced dispersion into the air.
5
meanwhile, to disable nebulizing, remove
your finger from the hole of the nebulizer
manual control to avoid the waste of drug,
optimizing its acquisition. Then exhale slow-
ly.
During expiration the vent bends outwards.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Y301p00

Tabla de contenido