Normal Operation; Use Of The Oven (If Present); Electrical Power Supply Failure - La Nordica TERMOCUCINOTTA EVO Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

After lighting the fire, leave the combustion air regulator open in the position shown:
FUEL
Wood
IMPORTANT:
do not add further wood between one complete load and the next;
do not suffocate the fire by closing the air intakes;
regular cleaning by a chimney sweep reduces fine particle emissions.
These instructions are backed by ENERGIA Legno SVIZZERA

NORMAL OPERATION

IMPORTANT: For safety reasons the door of the hearth can be opened only for the loading of the fuel. The hearth door must
always remain closed during operation or rest.
After having positioned the registers correctly, insert the indicated hourly wood load avoiding overloads that cause anomalous stresses and
deformations. You should always use the product with the door closed in order to avoid damages due to overheating (forge effect).
The inobservance of this rule makes the warranty expire.
For safety reasons the door of the appliances with constructive system 1, must be opened only for the loading of the fuel or for removing the
ashes, while during the operation and the rest, the door of the hearth must remain closed.
The appliances with constructive system 2 must be connected to their own flue. The operating with open door is allowed under supervision.
With the controls positioned on the front of the appliance it is possible to adjust the heat emission of the hearth. They have to be opened
according to the calorific need. The best combustion (with minimum emissions) is reached when, by loading the wood, most part of the air for
combustion flows through the secondary air register.
Never overload the appliance (see the hourly wood load in the table here below). Too much fuel and too much air for the combustion may
cause overheating and then damage the stove. you should always use the appliance with the door closed in order to avoid damages due to
overheating (forge effect). The inobservance of this rule makes the warranty expire.
The adjustment of the registers necessary to reach the rated calorific yield with a depression at the stack of 10 Pa (1,0 mm of column of water)
is the following one: see chapter TECHNICAL DESCRIPTION. The appliance works as an intermittent operating appliance.
In the event that the water temperature exceeds the tripping temperature of the safety devices, immediately suspend the
feeding of wood, and make sure that the water temperature and the flame decrease, eliminating the causes of the
overheating (if necessary by closing the air register).
If the water system is connected in the appliance, the hot water tap can be opened to speed up the cooling of the appliance.
Besides the adjustment of the air for the combustion, the intensity of the combustion and consequently the thermal performance
of the device is influenced by the stack. A good draught of the stack requires a stricter adjustment of air for combustion, while a poor draught
requires a more precise adjustment of air for combustion.
To verify the good combustion, check whether the smoke coming out from the stack is transparent.
If it is white, it means that the device is not properly adjusted or the wood is too wet; if instead the smoke is gray or black, it signals that the
combustion is not complete (it is necessary a greater quantity of secondary air).
WARNINg: When fuel is added onto the embers in the absence of a flame, a considerable amount of fumes may develop. Should
this happen, an explosive mixture of gas and air may form, and in extreme cases an explosion may occur. For safety reasons it is
advisable to perform a new lighting procedure with the use of small strips.

UsE OF THE OVEN (IF PREsENT)

Thanks to the air flow for the combustion, the temperature of the oven may become remarkably affected. A sufficient flue of the chimney and
of the channels, well cleaned for the flow of burning smokes around the oven are fundamental for a good cooking result. The oven pan may
be located on different plans. Thick cakes and big roasts must be introduced in the lowest level. Flat cakes and biscuits must reach the medium
level. The upper level may be used to heat or grill.
The oven pan and the chrome plated oven grille may be located on different plans (see chapter Technical Description - ACCESSORIES).
When cooking food with high humidity, cakes with fruit or fruit itself, water of condensation will be produced. During the cooking process
some water vapour in the form of drops of condensed water can deposit onto the top and the side of the door. It is a physical phenomenon.
By opening the door briefly and carefully (1 or 2 times, or even often in case of longer cooking times) you can let out the steam from the
cooking compartment and reduce condensation significantly.
The appliance is equipped with a cast iron furnace grill which can be removed using a specific handle. The upper position optimises the use
of the hotplate while the lower one optimises water and oven heating

ELECTRICAL POWER sUPPLY FAILURE

In the event of an unexpected electrical power supply failure during normal system operation, it will be necessary to carry out these simple
manoeuvres to prevent the water in the boiler starting to boil as a consequence of the lack of pump operation.
1. Raise the moveable furnace grill (if present ) to the highest level in order to reduce the exchange surface exposed to the heat of the flame.
2. Close the primary and secondary air registers in addition to turning the thermostat to 0 ( if present).
32
PRIMARY Air
Position 0
www.energia-legno.ch
Picture
ENgLIsH
sECONDARY Air
1/2 OPEN
8.
TERTIARY air
PRE-ADJUSTED

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Termocucinotta dsa

Tabla de contenido