be repeated. If the Operators move in the opposite direction to the
described direction, release the SET key, disconnect the control unit
from the power supply and change the setting of Dip Switch SW2 to
change the direction of run of the required operator without having
to rewire the connections. If the Operators sequence is correct, the
control unit completes the Auto programming stage by performing
a complete opening and closing cycle (keep the SET key pressed
until the end of the Auto Programming procedure). During the Auto
Programming procedure, the Deceleration cycle is set automatically at
approximately 15% of the complete cycle.
During Automatic Programming, instead of the SET key on the control
unit you can use the button on the remote, providing the remote has
been saved beforehand.
Warning: Automatic Programming is not available without limit
switches.

EXTENDED MENU 1

The control unit is factory set to allow direct selection exclusively of the
main menu functions. If you wish to enable the functions described in
Extended Menu 1, proceed as follows: select blinking LEV LED and
press SET once. The LED will start blinking. This means there will be
30 seconds to select the functions of Extended Menu 1 using the
SELECT and SET keys; once an additional 30 seconds have elapsed,
the control unit reverts to the main menu.
L1
PERSON PRESENT
L2
PEDESTRIAN /
SINGLE LEAF PUSHBUTTON
L3
PEDESTRIAN PUSHBUTTON /
DS3
L4
FOTOTEST
L5
DS2 STP IN CLOSING
L6
DS1 PARTIAL REVERSAL
L7
NC AS 8K2
LEV
MENU LEVEL
1. HOLD-TO-RUN:
The control unit provides the opportunity to set the "Hold-to-run"
function. If you wish to enable this function, proceed as follows: ensure
you have enabled Extended Menu 1 (alternate blinking 1 0 1 0 1 0 of
menu LED LEV) and then use the SEL key to select blinking LED L1
and press the SET key; LED L1 becomes steady on and the operation
will be completed. With hold-to-run enabled, using either the remotes
or the Pushbuttons to operate the gate, the following operation will be
obtained: the command must be maintained constantly to move the
gate. When the command is released, movement will stop immediately.
Repeat the procedure if you wish to restore the previous configuration.
2. SINGLE LEAF OR PED. BUTTON = OPEN, PED. BUTTON =
CLOSE:
The control unit allows a NO Pushbutton to be connected (CN2 input
no. 10) to activate the gate in Pedestrian Opening mode. It is however
possible to use this input to connect a NO pushbutton operating in
a different manner. If you wish to enable the "Single Leaf" function,
proceed as follows: ensure you have enabled Extended Menu 1
(alternate blinking 1 0 1 0 1 0 of menu LED LEV) and then use the SEL
key to select blinking LED L2 and press the SET key; LED L2 becomes
steady on and the operation will be completed. With this function
enabled, the Pushbutton can be used to activate exclusively Operator
1 (refer to the heading "Single Leaf"). In contrast, if you wish to enable
"OPEN-CLOSE" mode in order to use the Pedestrian Pushbutton to
activate exclusively opening of the gate and the P/P Pushbutton to
(CN2 input no. 11) to activate exclusively closing of the gate, repeat
the operation described above, pressing the SEL key twice (LED L2
will blink rapidly) instead of just once. Repeat the procedure if you wish
to restore the initial configuration.
3. PEDESTRIAN PUSHBUTTON / DS3:
The control unit allows a NO Pushbutton to be connected (CN2 input
no. 10) to activate the gate in Pedestrian Opening mode. However,
this input can be used to connect a DS3 photocell (NC): make sure
you have enabled Extended Menu 1 (alternate blinking 1 0 1 0 1 0 of
menu LED LEV) and then use the SEL key to select blinking LED L3
and press the SET key; LED L3 becomes steady on and the operation
26
COMUNELLO ®Copyright 2014 - All right reserved
ON
OFF
SINGLE LEAF
PEDESTRIAN
PUSHBUTTON
DS3
PEDESTRIAN
PUSHBUTTON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
1 FLASH
will be completed. Repeat the procedure if you wish to restore the
previous configuration.
4. FOTOTEST (Photocells test):
The control unit is factory set with the photocells test disabled. If you
wish to enable the photocells test proceed as follows: ensure you have
enabled Extended Menu 1 (blinking 1 0 1 0 1 of LED LEV) and then use
the SEL key to select blinking LED L4 and press the SET key; LED L4
becomes steady on and the operation will be completed. Repeat the
procedure if you wish to restore the previous configuration.
5. DS2 CLOSING STOP:
The control unit allows the operation of input DS2 to be modified. If
you want DS2 to trip also during closing (stopping of the gate leaf). If
in Automatic operating mode and once the passage is free, the gate
resumes the closing manoeuvre, proceed as follows: ensure you have
enabled Extended Menu 1 (alternate blinking 1 0 1 0 1 0 of menu
LED LEV) and then use the SEL key to select blinking LED L5 and
press the SET key; LED L5 becomes steady on and the operation will
be completed. Repeat the procedure if you wish to restore the initial
configuration.
6. DS1 PARTIAL REVERSAL:
The control unit allows the operation of input DS1 to be modified. If,
during a closing manoeuvre, you want DS1 to perform a partial reversal
(short reversal) of the gate leaf instead of a total reversal, proceed as
follows: ensure you have enabled Extended Menu 1 (alternate blinking
1 0 1 0 1 0 of menu LED LEV) and then use the SEL key to select
blinking LED L6 and press the SET key; LED L6 becomes steady on
and the operation will be completed. Repeat the procedure if you wish
to restore the initial configuration.
7. EMERGENCY STOP / 8K2:
The control unit allows the connection of an NC Emergency Stop
pushbutton (CN2 input LED LEV). However, this input can be switched
to an 8.2 KOhm resistive input: ensure you have enabled Extended
Menu 1 (alternate blinking 1 0 1 0 1 0 of menu LED LEV) and then
use the SEL key to select blinking LED L7 and press the SET key;
LED L7 becomes steady on and programming will be completed. A
change of the value read on the input will cause the control unit to
shut down irrespective of the gate movement currently in progress. An
additional gate movement command will be valid provided the correct
input value is restored and irrespective of the prior status the control
unit will execute the gate opening cycle. Repeat the procedure if you
wish to restore the initial configuration.
EXTENDED MENU 2
The control unit is factory set to allow direct selection exclusively of the
main menu functions.
If you wish to enable the functions described in Extended Menu 2,
proceed as follows: select blinking LED LEV and press SET twice. The
LED will start blinking alternately 1 1 0 1 1 0. This means there will
be 30 seconds to select the functions of Extended Menu 2 using the
SEL and SET keys; once an additional 30 seconds have elapsed, the
control unit reverts to the main menu.
L1
BRAKE
L2
DECELERATION
L3
ALWAYS CLOSE
L4
FOLLOW ME
L5
PEDESTRIAN TIME
L6
2
nd
CH MONOSTABLE
L7
REMOTE PRG
LEV
MENU LEVEL
1. BRAKE:
The control unit is factory set with the electronic brake function
disabled. If you wish to enable the function, proceed as follows: ensure
you have enabled Extended Menu 2 (alternate blinking 1 1 0 1 1 0 1
1 0 of menu LED LEV) and then use the SEL key to select blinking
LED L1 and press the SET key; LED L1 becomes steady on and the
operation will be completed.
ON
OFF
OFF
ON
ON
OFF
ON
OFF
PGM TIME