DRAINING SOLUTION TANK
To drain unused cleaning solution or recycled solution
from solution tank, follow steps below:
1. Remove clear drain hose from hose barb, position
hose over drain (Figure 32).
FIG. 32
2. Rinse out solution tank and solution flow system
with clean water to prevent clogging due to
chemical buildup.
3. Replace drain hose securely on hose barb when
empty.
BATTERY CHARGING
NOTE: Recharge batteries ONLY after a total of 30
minutes of use or more. This will prolong battery life.
The following charging instructions are intended
for the 24V charger supplied with the machine.
Only use a charger with the following
specifications to prevent battery damage.
CHARGER SPECIFICATIONS:
S
OUTPUT VOLTAGE - 24 VOLTS
S
OUTPUT CURRENT - 25 AMPS MAXIMUM
S
AUTOMATIC SHUTOFF CIRCUIT
S
FOR DEEP CYCLE BATTERY CHARGING
NOTE: For optimum machine operation, keep
batteries charged at all times. Never let batteries set in
a discharge condition for lengthy periods.
WARNING: Keep Sparks And Open Flame
Away. Keep Battery Hood Open When Charging.
FOR SAFETY: When servicing machine, wear
protective gloves and safety glasses when
handling batteries or battery cables. Avoid contact
with battery acid.
Speed Scrubt 1701 Plus (02–04)
All manuals and user guides at all-guides.com
1. Transport machine to a flat, dry surface in a well–
ventilated area for charging.
2. Turn off all switches and key.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.
3. Remove battery compartment hood.
4. Before charging, check the fluid level (A) in each
battery cell. If the battery plates (B) are exposed,
add just enough distilled water to cover plates.
DO NOT OVERFILL. Overfilled batteries can
overflow during charging due to fluid expansion.
Replace cell caps before charging (Figure 33).
A
FIG. 33
5. With charger's power supply cord unplugged,
connect charger to machine (Figure 34).
FIG. 34
NOTE: Once charger is connected to machine,
machine becomes inoperable.
6. Plug charger's power supply cord into a grounded
wall outlet (Figure 35).
Grounded
3 Hole Outlet
Ground Pin
FIG. 35
OPERATION
B
15