Machine Maintenance; Daily Maintenance; Weekly Maintenance - Nobles Speed Scrub 1710 Plus Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
FOR SAFETY: Do not operate charger unless cord
is properly grounded.
WARNING: Keep Sparks And Open Flame
Away. Keep Battery Hood Open When Charging.
7. The charger will automatically begin charging and
shut off when fully charged.
8. After charger has turned off, unplug charger from
machine then disconnect charger from wall outlet.
9. After charging, recheck the battery fluid level (A) in
each battery cell. The level should be 1 cm (3/8 in)
from the bottom of sight tubes (B). Add distilled
water if needed. DO NOT OVERFILL (Figure 36).
B
FIG. 36

MACHINE MAINTENANCE

To keep machine in good working condition, simply
follow the daily, weekly and monthly maintenance
procedures.
FOR SAFETY: When leaving or servicing machine,
stop on level surface and turn off machine.
WARNING: Disconnect Battery Cables Before
Servicing Machine.
ATTENTION: Contact an Authorized Service
Center for machine repairs. Machine repairs
performed by other than an authorized person will
void your warranty.
NOTE: If equipped with optional hour meter, record
machine hours when service was performed.

DAILY MAINTENANCE

(Every 4 Hours of Operation)
1. Remove and clean pad or brush. Never use soiled
pads when cleaning. Replace pad when it
becomes worn or loaded with residue.
2. Drain and rinse both tanks thoroughly.
3. Open clear lid, remove and clean the ball float
screen. Replace screen securely (Figure 37).
16
All manuals and user guides at all-guides.com
4. Open clear lid, remove and clean ESt filter, if
A
5. Raise squeegee and wipe it off with a dry cloth.
6. Clean machine housing with a nonabrasive,
7. Recharge batteries if needed.

WEEKLY MAINTENANCE

(Every 20 Hours of Operation)
1. Flush out tanks and solution lines. Pour 750mL
2. Remove inline strainer filter and rinse out. Before
3. Check fluid level in battery cells (See BATTERY
4. Clean battery tops to prevent corrosion (See
5. Check for loose or corroded battery cables.
FIG. 37
equipped. Replace filter securely.
Store squeegee in the up position to prevent
squeegee damage.
nonsolvent cleaner.
(24 oz) of an acetic acid solution with 11.3L (3 gal)
of hot water into solution tank. Over a floor drain,
activate solution flow briefly to fill solution line.
Shut off power and let machine set over night.
Rinse with clean water afterwards.
removing filter, be certain solution tank is empty.
Filter is located under machine at rear (Figure 38).
FIG. 38
MAINTENANCE).
BATTERY MAINTENANCE).
Speed Scrubt 1701 Plus (02–04)

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

608336608337609245

Tabla de contenido