Check the condition of the capsizing relay, sole-
noid valve and alternator, as well as their wiring,
connectors and terminations.
●
Undo the seals on the starter motor drainage
(see figure C) to drain off any condensation. Re-
seal the drainage again.
Every 1200th hour / At least once every 5 years:
●
Replace drive belt. See the instructions for re-
placement of drive belt in the operator's manual
for D4/D6.
Note! The table below shows which belts shall
be used for SOLAS-D4/D6.
IMPORTANT! The tightening torque differs from
the value given the operator's manual for
D4/D6. Tightening torque for SOLAS-D4/D6
is 45 ± 5 Nm (33.2 ± 3.7 lbf ft). Please refer to
figure B.
Drive belt variants for SOLAS-D4/D6
ENGINE
PART NO.
Standard:
D4
991587
D6
991586
With extra alternator:
D4
991590
D6
991588
With power steering pump:
D4
991591
D6
991589
LENGTH (mm)
1454
1396
1575
1517
1602
1544
C
English
7