Device Maintenance And Controls - Mikropor Mia Air Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 19
• If the power cord is damaged, the cable should only be changed by
the manufacturer, a service agency of the manufacturer or by a qualified
personnel to prevent any danger.

DEVICE MAINTENANCE AND CONTROLS

General Cleaning of the System
Unplug the device before cleaning.
• The general cleaning of the system is carried out daily by the user.
• The cleaning of the outer casing should be done daily with a
slightly damp soft cloth that does not leave moisture.
• It should be paid attention that no moisture enters
the inside surface.
• Abrasive cleaning materials should not be used.
Periodic Fuse Control and Switch Replacement
Please conduct the Fuse Control and Replacement when the fuse switch is turned on but not running
and your device is connected to the power outlet.
Please make sure that your device is turned off before conducting the Fuse Control and Replacement.
A- Please disconnect the power cord from the power outlet.
B- Open the fuse box and remove the broken fuse carefully.
C- Please install the spare fuse in the fuse box.
Please make sure that the Ampere rating of the Fuse does not exceed 4 Amps to prevent fire risk.
D- Close the fuse box and insert the power cord plug into the power outlet.
Checking and Replacing the Front Filters
Unplug the device before replacing the filters.
• Checking and replacing the front filters should be done monthly by the user. The duration of the filters
depends on the frequency of use and the level of dirtiness in the area where the product is being used.
12
A
B
C
D

Publicidad

Tabla de contenido
loading

Productos relacionados para Mikropor Mia Air

Tabla de contenido