Descargar Imprimir esta página

Real Time Clock; Energy Saving - Evco EVBOX1 Manual Del Usuario

Cuadro de distribución para cámaras frigoríficas monofásicas
Ocultar thumbs Ver también para EVBOX1:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EVCO S.p.A. | EVBOX1 | Data sheet ver. 3.0 | Code 104BOX1E304 | Page 6 of 8 | PT 25/19
u3
0
240
s
u4
0
1
- - -
u5
-99.0
99.0
°C/°F (1)
u6
1
120
min
u7
-99.0
99.0
°C/°F (1)
u9
0
1
- - -
u11
0
12
- - -
PARAM.
MIN.
MAX.
U.M.
Hr0
0
1
- - -
PARAM.
MIN.
MAX.
U.M.
HE2
0
999
min
H01
0
23
h
H02
0
24
h
H03
0
23
h
H04
0
24
h
H05
0
23
h
H06
0
24
h
H07
0
23
h
H08
0
24
h
H09
0
23
h
H10
0
24
h
H11
0
23
h
H12
0
24
h
H13
0
23
h
H14
0
24
h
PARAM.
MIN.
MAX.
U.M.
Hd1
h0
h - -
h
Hd2
h0
h - -
h
Hd3
h0
h - -
h
Hd4
h0
h - -
h
Hd5
h0
h - -
h
Hd6
h0
h - -
h
PARAM.
MIN.
MAX.
U.M.
Sd0
1
30
min
Sd1
1
30
min
Sd2
1
240
min
Sd3
0
1
- - -
Sd4
0
1
- - -
Sd5
0
1
- - -
Sd6
0
2
- - -
PARAM.
MIN.
MAX.
U.M.
PA1
-99
999
- - -
PA2
-99
999
- - -
rE0
0
240
min
rE1
0
5
- - -
PARAM.
MIN.
MAX.
U.M.
LA
1
247
- - -
Lb
0
3
- - -
LP
0
2
- - -
bLE
0
99
- - -
Notes:
(1)
the unit of measurement depends on P2 parameter
(2)
the unit of measurement depends on P9 and P10 parameters
(3)
properly set the parameters relative to the regulators after setting P2 parameter
(4)
the formula for the calculation of the CPT temperature is the following one:
CPT temperature = {[(P7 parameter) x (inlet air temperature)] + [(100 - P7 parameter) x (outlet air temperature)] : 100}
(5)
the value depends on P2 parameter (0.1 °C or 1 °C)
(6)
the differential of h02 and h03 parameters is 2.0 °C/4 °F
(7)
the differential of h13 parameter is 2.0 bar g/PSI g
(8)
F13 and F14 parameters have effect when the compressor is switched off
(9)
F13 and F14 parameters have effect when the compressor is switched on
(10)
F13 and F14 parameters have effect when the evaporator temperature is below the temperature set with F1 parameter
(11)
F13 and F14 parameters have effect when the compressor is switched on and the evaporator temperature is below the temperature set with F1 parameter.
10
if C14 = 0, delay in switching off the compressor after the pump down valve is switched off | if C14 = 1 or 2, maximum time between the
pump down valve is switched off and the compressor is switched off; see also h10 in EVB1246 and EVB1256
1
enabling the alarm output deactivation silencing the alarm buzzer (1 = YES)
-1.0
if P4 = 0, 1, 2 or 3, room temperature below which the door heater is switched on | if P4 = 4, CPT temperature below which the door heater
is switched on ("u5 - 2.0 °C/4 °F)
5
time the demisting heater is switched on
-5.0
neutral zone value of the neutral zone operation heater ("working setpoint + u7")
1
enabling the alarm buzzer (1 = YES)
3
load managed by the digital output K6 (not available in EVB1204 and EVB1214) (0 = reserved; 1 = demisting heater; 2 = auxiliary output;
3 = alarm output; 4 = door heater; 5 = neutral zone operation heater; 6 = condenser fan; 7 = compressor 2; 8 = defrost 2;
9 = evaporator fan 2; 10 = pump down valve, reserved in EVB1246 and EVB1256; 11 = on/stand-by; 12 = man in room)
DEF.

REAL TIME CLOCK

1
enabling the real time clock (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX module is connected; 1 = YES)
DEF.

ENERGY SAVING

0
maximum duration of the "energy saving" function due to the effect of the absence of the door switch input activations; see also r4, F13, F14,
i10 (0 = the function will last as long as the input will be deactivated)
0
time the "energy saving" function is activated on Monday (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX
module is connected; see also r4, F13, F14 and H02)
0
duration of the "energy saving" function on Monday (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX module is
connected; see also r4, F13, F14 and H01)
0
time the "energy saving" function is activated on Tuesday (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX
module is connected; see also r4, F13, F14 and H04)
0
duration of the "energy saving" function on Tuesday (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX module
is connected; see also r4, F13, F14 and H03)
0
time the "energy saving" function is activated on Wednesday (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX
module is connected; see also r4, F13, F14 and H06)
0
duration of the "energy saving" function on Wednesday (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX module
is connected; see also r4, F13, F14 and H05)
0
time the "energy saving" function is activated on Thursday (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX
module is connected; see also r4, F13, F14 and H08)
0
duration of the "energy saving" function on Thursday (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX module
is connected; see also r4, F13, F14 and H07)
0
time the "energy saving" function is activated on Friday (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX module
is connected; see also r4, F13, F14 and H10)
0
duration of the "energy saving" function on Friday (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX module is
connected; see also r4, F13, F14 and H09)
0
time the "energy saving" function is activated on Saturday (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX
module is connected; see also r4, F13, F14 and H12)
0
duration of the "energy saving" function on Saturday (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX module
is connected; see also r4, F13, F14 and H11)
0
time the "energy saving" function is activated on Sunday (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX
module is connected; see also r4, F13, F14 and H14)
0
duration of the "energy saving" function on Sunday (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX module is
connected; see also r4, F13, F14 and H13)
DEF.
REAL TIME DEFROST (only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX module is connected; only if d8 = 4)
0
time the first daily defrost is activated (h - - = absent)
0
time the second daily defrost is activated (h - - = absent)
0
time the third daily defrost is activated (h - - = absent)
0
time the fourth daily defrost is activated (h - - = absent)
0
time the fifth daily defrost is activated (h - - = absent)
0
time the sixth daily defrost is activated (h - - = absent)
DEF.
DATA LOGGING (only available in EVB1214, EVB1216 and EVB1256 without mag thermic circuit breaker o mag thermic circuit breaker and
residual current device)
30
writing interval in "HACCP" mode
1
writing interval in "service" mode
60
duration of the "service" writing mode
0
enabling the auxiliary 3 temperature probe (1 = YES)
0
enabling the writing of the room temperature value (1 = YES)
1
kind of decimal separator (0 = comma; 1 = point)
1
kind of auxiliary 2 temperature probe and auxiliary 3 temperature probe (0 = reserved; 1 = NTC; 2 = Pt 1000); also look at P0
DEF.
EVLINK WI-FI MODULE (only available in model EVB1206N9XWX)
426
first level password
824
second level password
60
sampling interval
4
temperature selection for data logger (0 = none; 1 = cabinet; 2 = evaporator; 3 = auxiliary; 4 = cabinet and evaporator; 5 = all)
DEF.
MODBUS RS-485
247
device address
2
baud rate (0 = 2,400 baud; 1 = 4,800 baud; 2 = 9,600 baud; 3 = 19,200 baud)
2
parity (0 = none; 1 = odd; 2 = even)
1
Serial port configuration for connectivity (only available in model EVB1206N9XWX; 0 = free, 1 = forced for EPoCA, 2-99 = EPoCA local network
address)

Publicidad

loading