Adjust Brake Pad (100 Pro, 200 Pro, 300 Pro only)
The brake mechanism has been adjusted at the factory. However, over time due to chain stretch and brake pad wear, it may need
to be adjusted. To replace/adjust brake pad, use the following procedure:
1. Back off resistance until it the knob
stops turning (counterclockwise). Then
turn clockwise 180 degrees (1/2 turn).
Adjust Brake Pad (400 Pro only)
The brake mechanism has been adjusted at the factory and has an electronically adjusted brake pad. Instead of manually adjust-
ing the brake pad, plug the indoor cycle in for 60 seconds and then remove the plug. This resets and places the brake pad in the
furthest position (lightest resistance).
CHAPTER 6: PREVENTATIVE MAINTENANCE
Performing necessary preventative maintenance is key to keeping the CycleOps Pro Series indoor cycle in proper working condi-
tion. Following the recommended maintenance procedures will help extend the life of the CycleOps Pro Series indoor cycle.
DAILY
After each day the indoor cycle is ridden, perform the following:
•
Release all tension from the resistance knob.
•
Wipe down the handlebar.
•
Wipe down seat/seat post.
•
Wipe down fl ywheel.
•
Wipe down frame.
•
Wipe down chain guard.
•
Wipe down resistance knob.
•
Wipe down handlebar post.
•
Wipe down stabilizers.
NOTE: Never use abrasive cleaning liquids or petroleum-based solvents when wiping down the indoor cycle. A standard bike pol-
ish can be used on the painted parts of the indoor cycle.
2. Loosen the clamping bolts with a
5mm Allen wrench. Align the brake
pad by sliding it towards the fl ywheel.
Stop when the pad just touches the
fl ywheel. Align the arc of the brake
pad with the arc of the fl ywheel.
3. Tighten clamping bolts to 50 in-lbs.
When properly adjusted, the CycleOps
Pro Series indoor cycle should register
around 30 watts at 90 rpm at the lowest
resistance setting (can only be validated
on 300 Pro).
11