Spark Plug Inspection and Replacement

1. Turn off LP cylinder and remove it.
2. Pull spark plug cap off of spark plug.
3. Remove spark plug by turning counter-clockwise and
inspect it.
Note: If the plug is oily or has carbon build up on it,
clean the plug using a high flash-point solvent and a
wire brush or other suitable tool.
Note: If the spark plug electrodes are corroded or
damaged, or if the insulator is cracked, replace the
plug. Use Only Part # 56384271. DO NOT use any
other spark plug!
4. Measure the gap with a wire-type thickness gauge.
The correct gap is .025 in (.635 mm). If the gap is
incorrect, carefully bend the side electrode with a
suitable tool to obtain the correct gap.
A: Insulator
B: Center Electrode
C: Plug Gap
D: Side Electrode

Air Filter Inspection and Replacement

1. Push machine to level surface.
2. Turn off LP cylinder and remove it.
3. Turn the two knobs 1/4 turn counter-clockwise and
remove the filter cover.
4. Loosen clamp that retains filter and remove the air
filter.
CAUTION! Do not wash the air cleaner filters. Do not
oil the air filters. Do not use pressurized air to clean
the air filters.
For cleaning machines, parts & supplies click/visit www.southeasternequipment.net
5. Inspect both primary and secondary air filters. If
necessary, clean primary filter by lightly tapping and
wipe seal ends with a clean cloth. If primary filter
cannot be cleaned, is bent, or damaged, it must be
replaced. (Part # 56384272) If secondary filter is
dirty, do not attempt to clean it. Replace it with a
new filter (Part #56384268).
6. Check the intake hose for cracks or damage.
7. Install filters and replace cover.

Inspect Fuel Hose and Connections

1. Push machine to level surface.
2. Turn off LP cylinder and remove it.
3. Inspect hoses for abrasions and other signs of wear.
Replace all worn or damaged hoses.
4. Check for gas leaks by spreading a soapy water
solution around all connections while the LP cylinder
is reconnected and the service valve is turned ON.
5. If a leak is detected, turn off the LP cylinder. If the
leak is in a hose, replace it. If the leak is at a fitting,
loosen and clean it. Apply pipe-sealing compound
and re-tighten it.
6. Recheck for leaks using a soapy water solution. If
leaks persist at fittings, replace them and recheck
with a soapy water solution once more.